| 1 | +ID,Units,Location,Direction,Theta_0,Blocks,Family,Theta_1,Comment |
| 2 | +B.20.22.001,SF,4,"1,2",4320,144,,0.6,"B2022.001 Curtain Walls - Generic Midrise Stick-Built Curtain wall, Config: Monolithic, Lamination: Unknown, Glass Type: Unknown, Details: Aspect ratio = 6:5, Other details Unknown" |
| 3 | +B.30.11.011,SF,4,0,3888,38,,1.3,"B3011.011 Concrete tile roof, tiles secured and compliant with UBC94" |
| 4 | +C.10.11.001a,LF,4,"1,2",1440,14,,0.2,"C1011.001a Wall Partition, Type: Gypsum with metal studs, Full Height, Fixed Below, Fixed Above" |
| 5 | +C.30.11.001a,LF,4,"1,2",108.9,1,,0.7,"C3011.001a Wall Partition, Type: Gypsum + Wallpaper, Full Height, Fixed Below, Fixed Above" |
| 6 | +C.30.27.001,SF,4,0,10800,108,,0.2,"C3027.001 Raised Access Floor, non seismically rated." |
| 7 | +C.30.32.001a,SF,4,0,12960,51,,0,"C3032.001a Suspended Ceiling, SDC A,B,C, Area (A): A < 250, Vert support only" |
| 8 | +C.30.32.001a,SF,4,0,720,2,,0,"C3032.001a Suspended Ceiling, SDC A,B,C, Area (A): A < 250, Vert support only" |
| 9 | +C.30.32.001a,SF,4,0,432,1,,0,"C3032.001a Suspended Ceiling, SDC A,B,C, Area (A): A < 250, Vert support only" |
| 10 | +C.30.32.001a,SF,4,0,288,1,,0,"C3032.001a Suspended Ceiling, SDC A,B,C, Area (A): A < 250, Vert support only" |
| 11 | +D.20.21.011a,LF,4,0,604.8,1,,0.7,"D2021.011a Cold or Hot Potable - Small Diameter Threaded Steel - (2.5 inches in diameter or less), SDC A or B, PIPING FRAGILITY" |
| 12 | +D.30.41.012a,LF,4,0,288,1,,0.2,"D3041.012a HVAC Galvanized Sheet Metal Ducting - 6 sq. ft cross sectional area or greater, SDC A or B" |
| 13 | +D.30.41.011a,LF,4,0,1080,1,,0.2,"D3041.011a HVAC Galvanized Sheet Metal Ducting less than 6 sq. ft in cross sectional area, SDC A or B" |
| 14 | +D.30.41.031a,EA,4,0,129.6,12,,0.5,"D3041.031a HVAC Drops / Diffusers in suspended ceilings - No independent safety wires, SDC A or B" |
| 15 | +D.30.41.041a,EA,4,0,72,7,,0.2,"D3041.041a Variable Air Volume (VAV) box with in-line coil, SDC A or B" |
| 16 | +D.30.41.041a,EA,4,0,28.8,2,,0.5,"D3041.041a Variable Air Volume (VAV) box with in-line coil, SDC A or B" |
| 17 | +C.30.34.001,EA,4,0,216,216,,0.3,C3034.001 Independent Pendant Lighting - non seismic |
| 18 | +C.30.34.001,EA,4,0,216,216,,0.3,C3034.001 Independent Pendant Lighting - non seismic |
| 19 | +D.40.11.021a,LF,4,0,2880,2,,0.1,"D4011.021a Fire Sprinkler Water Piping - Horizontal Mains and Branches - Old Style Victaulic - Thin Wall Steel - No bracing, SDC A or B, PIPING FRAGILITY" |
| 20 | +D.40.11.031a,EA,4,0,129.6,1,,0.2,"D4011.031a Fire Sprinkler Drop Standard Threaded Steel - Dropping into unbraced lay-in tile SOFT ceiling - 6 ft. long drop maximum, SDC A or B" |
| 21 | +B.20.22.001,SF,3,"1,2",4320,144,,0.6,"B2022.001 Curtain Walls - Generic Midrise Stick-Built Curtain wall, Config: Monolithic, Lamination: Unknown, Glass Type: Unknown, Details: Aspect ratio = 6:5, Other details Unknown" |
| 22 | +B.30.11.011,SF,3,0,3888,38,,1.3,"B3011.011 Concrete tile roof, tiles secured and compliant with UBC94" |
| 23 | +C.10.11.001a,LF,3,"1,2",1440,14,,0.2,"C1011.001a Wall Partition, Type: Gypsum with metal studs, Full Height, Fixed Below, Fixed Above" |
| 24 | +C.30.11.001a,LF,3,"1,2",108.9,1,,0.7,"C3011.001a Wall Partition, Type: Gypsum + Wallpaper, Full Height, Fixed Below, Fixed Above" |
| 25 | +C.30.27.001,SF,3,0,10800,108,,0.2,"C3027.001 Raised Access Floor, non seismically rated." |
| 26 | +C.30.32.001a,SF,3,0,12960,51,,0,"C3032.001a Suspended Ceiling, SDC A,B,C, Area (A): A < 250, Vert support only" |
| 27 | +C.30.32.001a,SF,3,0,720,2,,0,"C3032.001a Suspended Ceiling, SDC A,B,C, Area (A): A < 250, Vert support only" |
| 28 | +C.30.32.001a,SF,3,0,432,1,,0,"C3032.001a Suspended Ceiling, SDC A,B,C, Area (A): A < 250, Vert support only" |
| 29 | +C.30.32.001a,SF,3,0,288,1,,0,"C3032.001a Suspended Ceiling, SDC A,B,C, Area (A): A < 250, Vert support only" |
| 30 | +D.20.21.011a,LF,3,0,604.8,1,,0.7,"D2021.011a Cold or Hot Potable - Small Diameter Threaded Steel - (2.5 inches in diameter or less), SDC A or B, PIPING FRAGILITY" |
| 31 | +D.30.41.012a,LF,3,0,288,1,,0.2,"D3041.012a HVAC Galvanized Sheet Metal Ducting - 6 sq. ft cross sectional area or greater, SDC A or B" |
| 32 | +D.30.41.011a,LF,3,0,1080,1,,0.2,"D3041.011a HVAC Galvanized Sheet Metal Ducting less than 6 sq. ft in cross sectional area, SDC A or B" |
| 33 | +D.30.41.031a,EA,3,0,129.6,12,,0.5,"D3041.031a HVAC Drops / Diffusers in suspended ceilings - No independent safety wires, SDC A or B" |
| 34 | +D.30.41.041a,EA,3,0,72,7,,0.2,"D3041.041a Variable Air Volume (VAV) box with in-line coil, SDC A or B" |
| 35 | +D.30.41.041a,EA,3,0,28.8,2,,0.5,"D3041.041a Variable Air Volume (VAV) box with in-line coil, SDC A or B" |
| 36 | +C.30.34.001,EA,3,0,216,216,,0.3,C3034.001 Independent Pendant Lighting - non seismic |
| 37 | +C.30.34.001,EA,3,0,216,216,,0.3,C3034.001 Independent Pendant Lighting - non seismic |
| 38 | +D.40.11.021a,LF,3,0,2880,2,,0.1,"D4011.021a Fire Sprinkler Water Piping - Horizontal Mains and Branches - Old Style Victaulic - Thin Wall Steel - No bracing, SDC A or B, PIPING FRAGILITY" |
| 39 | +D.40.11.031a,EA,3,0,129.6,1,,0.2,"D4011.031a Fire Sprinkler Drop Standard Threaded Steel - Dropping into unbraced lay-in tile SOFT ceiling - 6 ft. long drop maximum, SDC A or B" |
| 40 | +B.20.22.001,SF,2,"1,2",4320,144,,0.6,"B2022.001 Curtain Walls - Generic Midrise Stick-Built Curtain wall, Config: Monolithic, Lamination: Unknown, Glass Type: Unknown, Details: Aspect ratio = 6:5, Other details Unknown" |
| 41 | +B.30.11.011,SF,2,0,3888,38,,1.3,"B3011.011 Concrete tile roof, tiles secured and compliant with UBC94" |
| 42 | +C.10.11.001a,LF,2,"1,2",1440,14,,0.2,"C1011.001a Wall Partition, Type: Gypsum with metal studs, Full Height, Fixed Below, Fixed Above" |
| 43 | +C.30.11.001a,LF,2,"1,2",108.9,1,,0.7,"C3011.001a Wall Partition, Type: Gypsum + Wallpaper, Full Height, Fixed Below, Fixed Above" |
| 44 | +C.30.27.001,SF,2,0,10800,108,,0.2,"C3027.001 Raised Access Floor, non seismically rated." |
| 45 | +C.30.32.001a,SF,2,0,12960,51,,0,"C3032.001a Suspended Ceiling, SDC A,B,C, Area (A): A < 250, Vert support only" |
| 46 | +C.30.32.001a,SF,2,0,720,2,,0,"C3032.001a Suspended Ceiling, SDC A,B,C, Area (A): A < 250, Vert support only" |
| 47 | +C.30.32.001a,SF,2,0,432,1,,0,"C3032.001a Suspended Ceiling, SDC A,B,C, Area (A): A < 250, Vert support only" |
| 48 | +C.30.32.001a,SF,2,0,288,1,,0,"C3032.001a Suspended Ceiling, SDC A,B,C, Area (A): A < 250, Vert support only" |
| 49 | +D.20.21.011a,LF,2,0,604.8,1,,0.7,"D2021.011a Cold or Hot Potable - Small Diameter Threaded Steel - (2.5 inches in diameter or less), SDC A or B, PIPING FRAGILITY" |
| 50 | +D.30.41.012a,LF,2,0,288,1,,0.2,"D3041.012a HVAC Galvanized Sheet Metal Ducting - 6 sq. ft cross sectional area or greater, SDC A or B" |
| 51 | +D.30.41.011a,LF,2,0,1080,1,,0.2,"D3041.011a HVAC Galvanized Sheet Metal Ducting less than 6 sq. ft in cross sectional area, SDC A or B" |
| 52 | +D.30.41.031a,EA,2,0,129.6,12,,0.5,"D3041.031a HVAC Drops / Diffusers in suspended ceilings - No independent safety wires, SDC A or B" |
| 53 | +D.30.41.041a,EA,2,0,72,7,,0.2,"D3041.041a Variable Air Volume (VAV) box with in-line coil, SDC A or B" |
| 54 | +D.30.41.041a,EA,2,0,28.8,2,,0.5,"D3041.041a Variable Air Volume (VAV) box with in-line coil, SDC A or B" |
| 55 | +C.30.34.001,EA,2,0,216,216,,0.3,C3034.001 Independent Pendant Lighting - non seismic |
| 56 | +C.30.34.001,EA,2,0,216,216,,0.3,C3034.001 Independent Pendant Lighting - non seismic |
| 57 | +D.40.11.021a,LF,2,0,2880,2,,0.1,"D4011.021a Fire Sprinkler Water Piping - Horizontal Mains and Branches - Old Style Victaulic - Thin Wall Steel - No bracing, SDC A or B, PIPING FRAGILITY" |
| 58 | +D.40.11.031a,EA,2,0,129.6,1,,0.2,"D4011.031a Fire Sprinkler Drop Standard Threaded Steel - Dropping into unbraced lay-in tile SOFT ceiling - 6 ft. long drop maximum, SDC A or B" |
| 59 | +B.20.22.001,SF,1,"1,2",4320,144,,0.6,"B2022.001 Curtain Walls - Generic Midrise Stick-Built Curtain wall, Config: Monolithic, Lamination: Unknown, Glass Type: Unknown, Details: Aspect ratio = 6:5, Other details Unknown" |
| 60 | +B.30.11.011,SF,1,0,3888,38,,1.3,"B3011.011 Concrete tile roof, tiles secured and compliant with UBC94" |
| 61 | +C.10.11.001a,LF,1,"1,2",1440,14,,0.2,"C1011.001a Wall Partition, Type: Gypsum with metal studs, Full Height, Fixed Below, Fixed Above" |
| 62 | +C.30.11.001a,LF,1,"1,2",108.9,1,,0.7,"C3011.001a Wall Partition, Type: Gypsum + Wallpaper, Full Height, Fixed Below, Fixed Above" |
| 63 | +C.30.27.001,SF,1,0,10800,108,,0.2,"C3027.001 Raised Access Floor, non seismically rated." |
| 64 | +C.30.32.001a,SF,1,0,12960,51,,0,"C3032.001a Suspended Ceiling, SDC A,B,C, Area (A): A < 250, Vert support only" |
| 65 | +C.30.32.001a,SF,1,0,720,2,,0,"C3032.001a Suspended Ceiling, SDC A,B,C, Area (A): A < 250, Vert support only" |
| 66 | +C.30.32.001a,SF,1,0,432,1,,0,"C3032.001a Suspended Ceiling, SDC A,B,C, Area (A): A < 250, Vert support only" |
| 67 | +C.30.32.001a,SF,1,0,288,1,,0,"C3032.001a Suspended Ceiling, SDC A,B,C, Area (A): A < 250, Vert support only" |
| 68 | +D.20.21.011a,LF,1,0,604.8,1,,0.7,"D2021.011a Cold or Hot Potable - Small Diameter Threaded Steel - (2.5 inches in diameter or less), SDC A or B, PIPING FRAGILITY" |
| 69 | +D.30.41.012a,LF,1,0,288,1,,0.2,"D3041.012a HVAC Galvanized Sheet Metal Ducting - 6 sq. ft cross sectional area or greater, SDC A or B" |
| 70 | +D.30.41.011a,LF,1,0,1080,1,,0.2,"D3041.011a HVAC Galvanized Sheet Metal Ducting less than 6 sq. ft in cross sectional area, SDC A or B" |
| 71 | +D.30.41.031a,EA,1,0,129.6,12,,0.5,"D3041.031a HVAC Drops / Diffusers in suspended ceilings - No independent safety wires, SDC A or B" |
| 72 | +D.30.41.041a,EA,1,0,72,7,,0.2,"D3041.041a Variable Air Volume (VAV) box with in-line coil, SDC A or B" |
| 73 | +D.30.41.041a,EA,1,0,28.8,2,,0.5,"D3041.041a Variable Air Volume (VAV) box with in-line coil, SDC A or B" |
| 74 | +C.30.34.001,EA,1,0,216,216,,0.3,C3034.001 Independent Pendant Lighting - non seismic |
| 75 | +C.30.34.001,EA,1,0,216,216,,0.3,C3034.001 Independent Pendant Lighting - non seismic |
| 76 | +D.40.11.021a,LF,1,0,2880,2,,0.1,"D4011.021a Fire Sprinkler Water Piping - Horizontal Mains and Branches - Old Style Victaulic - Thin Wall Steel - No bracing, SDC A or B, PIPING FRAGILITY" |
| 77 | +D.40.11.031a,EA,1,0,129.6,1,,0.2,"D4011.031a Fire Sprinkler Drop Standard Threaded Steel - Dropping into unbraced lay-in tile SOFT ceiling - 6 ft. long drop maximum, SDC A or B" |
| 78 | +C.20.11.001a,EA,4,"1,2",2.9,2,,0.2,C2011.001a Prefabricated steel stair with steel treads and landings with seismic joints that accommodate drift. |
| 79 | +D.50.12.021a,EA,4,0,1,1,,0.4,D5012.021a Low Voltage Switchgear - Capacity: 100 to <350 Amp - Unanchored equipment that is not vibration isolated - Equipment fragility only |
| 80 | +C.20.11.001a,EA,3,"1,2",2.9,2,,0.2,C2011.001a Prefabricated steel stair with steel treads and landings with seismic joints that accommodate drift. |
| 81 | +D.50.12.021a,EA,3,0,1,1,,0.4,D5012.021a Low Voltage Switchgear - Capacity: 100 to <350 Amp - Unanchored equipment that is not vibration isolated - Equipment fragility only |
| 82 | +C.20.11.001a,EA,2,"1,2",2.9,2,,0.2,C2011.001a Prefabricated steel stair with steel treads and landings with seismic joints that accommodate drift. |
| 83 | +D.50.12.021a,EA,2,0,1,1,,0.4,D5012.021a Low Voltage Switchgear - Capacity: 100 to <350 Amp - Unanchored equipment that is not vibration isolated - Equipment fragility only |
| 84 | +C.20.11.001a,EA,1,"1,2",2.9,2,,0.2,C2011.001a Prefabricated steel stair with steel treads and landings with seismic joints that accommodate drift. |
| 85 | +D.50.12.021a,EA,1,0,1,1,,0.4,D5012.021a Low Voltage Switchgear - Capacity: 100 to <350 Amp - Unanchored equipment that is not vibration isolated - Equipment fragility only |
| 86 | +D.10.14.011,EA,roof,0,2,2,,0.7,"D1014.011 Traction Elevator - Applies to most California Installations 1976 or later, most western states installations 1982 or later and most other U.S installations 1998 or later." |
| 87 | +D.30.31.011a,EA,roof,0,3,3,,0.1,D3031.011a Chiller - Capacity: < 100 Ton - Unanchored equipment that is not vibration isolated - Equipment fragility only |
| 88 | +D.30.31.021a,EA,roof,0,3,3,,0.1,D3031.021a Cooling Tower - Capacity: < 100 Ton - Unanchored equipment that is not vibration isolated - Equipment fragility only |
| 89 | +D.30.52.011a,EA,roof,0,13,13,,0.2,D3052.011a Air Handling Unit - Capacity: <5000 CFM - Unanchored equipment that is not vibration isolated - Equipment fragility only |
| 90 | +D.50.12.013a,EA,roof,0,2.9,2,,0.5,D5012.013a Motor Control Center - Capacity: all - Unanchored equipment that is not vibration isolated - Equipment fragility only |
| 91 | +B.10.44.101,SF,1--4,"1,2",288,2,,,Slender concrete wall |
| 92 | +B.10.49.012,EA,1--4,"1,2",21,21,,,RC slab-column connections |