@@ -432,10 +432,13 @@ def test_cleaning_mode_options() -> None:
432432 CleaningMode .VACUUM ,
433433 ),
434434 (
435- VacuumModes .OFF .code ,
435+ # 105 is the wire code the device reports for mop-only cleaning,
436+ # shared by VacuumModes.OFF and VacuumModes.GENTLE.
437+ 105 ,
436438 WaterModes .STANDARD .code ,
437439 CleanRoutes .STANDARD .code ,
438440 CleaningMode .MOP ,
441+
439442 ),
440443 (
441444 VacuumModes .CUSTOMIZED .code ,
@@ -473,7 +476,9 @@ def test_current_cleaning_mode_with_main_brush_lift() -> None:
473476 is_support_main_brush_up_down_supported = True ,
474477 is_water_slide_mode_supported = True ,
475478 )
476- status_trait .fan_power = VacuumModes .OFF .code
479+ # 105 is the wire code the device reports for mop-only cleaning,
480+ # shared by VacuumModes.OFF and VacuumModes.GENTLE.
481+ status_trait .fan_power = 105
477482 status_trait .water_box_mode = 235
478483 status_trait .mop_mode = CleanRoutes .STANDARD .code
479484
@@ -590,7 +595,7 @@ def test_get_cleaning_mode_parameters_qrevo_edge_2() -> None:
590595
591596 assert get_cleaning_mode_parameters (CleaningMode .MOP , status_trait ._device_features_trait ) == [
592597 {
593- "fan_power" : VacuumModes .OFF . code ,
598+ "fan_power" : 105 , # Wire code shared by VacuumModes.OFF and VacuumModes.GENTLE
594599 "water_box_mode" : 235 ,
595600 "mop_mode" : CleanRoutes .STANDARD .code ,
596601 }
@@ -620,7 +625,7 @@ def test_get_cleaning_mode_parameters_without_clean_route_setting() -> None:
620625 ]
621626 assert get_cleaning_mode_parameters (CleaningMode .MOP , status_trait ._device_features_trait ) == [
622627 {
623- "fan_power" : VacuumModes .OFF . code ,
628+ "fan_power" : 105 , # Wire code shared by VacuumModes.OFF and VacuumModes.GENTLE
624629 "water_box_mode" : WaterModes .STANDARD .code ,
625630 }
626631 ]
@@ -646,7 +651,7 @@ def test_get_cleaning_mode_parameters_water_slide_device() -> None:
646651 ]
647652 assert get_cleaning_mode_parameters (CleaningMode .MOP , status_trait ._device_features_trait ) == [
648653 {
649- "fan_power" : VacuumModes .OFF . code ,
654+ "fan_power" : 105 , # Wire code shared by VacuumModes.OFF and VacuumModes.GENTLE
650655 "water_box_mode" : 235 ,
651656 "mop_mode" : CleanRoutes .STANDARD .code ,
652657 }
@@ -812,7 +817,26 @@ def test_current_cleaning_mode_gentle_not_mop_without_pure_mop() -> None:
812817 assert status_trait .current_cleaning_mode == CleaningMode .VAC_AND_MOP
813818
814819
815- def test_water_slide_mode_mapping () -> None :
820+ def test_fan_speed_name_off_on_pure_mop_device () -> None :
821+ """Code 105 reports as off on pure-mop devices, where OFF is the offered mode."""
822+ status_trait = _create_cleaning_mode_status_trait ()
823+ status_trait .fan_power = 105
824+
825+ assert status_trait .fan_speed_mapping [105 ] == "off"
826+ assert status_trait .fan_speed_name == "off"
827+
828+
829+ def test_fan_speed_name_gentle_without_pure_mop () -> None :
830+ """Code 105 reports as gentle on devices without pure mop, where GENTLE is offered."""
831+ status_trait = _create_cleaning_mode_status_trait (is_pure_clean_mop_supported = False )
832+ status_trait .fan_power = 105
833+
834+ assert status_trait .fan_speed_mapping [105 ] == "gentle"
835+ assert status_trait .fan_speed_name == "gentle"
836+
837+
838+
839+ def test_water_slide_mode_mapping () -> None :
816840 """Test feature-aware water mode mapping for water slide mode devices."""
817841 short_model = mock_data .A114_PRODUCT_DATA ["model" ].split ("." )[- 1 ]
818842 features = DeviceFeatures .from_feature_flags (
0 commit comments