| title | Events |
|---|---|
| sidebar_label | Events |
Events in IdLE provide a structured way to observe what happens during the execution of a lifecycle plan. They are designed to make plan execution transparent for hosts, operators, and tooling without coupling the core engine to any specific logging, monitoring, or UI framework.
This document explains the conceptual model behind events in IdLE, their lifecycle, and how they are intended to be consumed.
This document covers:
- Why events exist in IdLE
- Where and when events are created
- How events are collected and exposed
- Event types, levels and data fields
- Responsibilities of engine, steps, and host environments
- Recommended usage patterns
Out of scope:
- Logging frameworks or telemetry backends
- Implementation details of specific steps
IdLE events are not a logging system.
They represent semantic execution milestones, such as:
- a plan starting or completing
- a step being executed or skipped
- a step emitting a domain-relevant message
The core engine does not decide:
- where events are stored
- how they are rendered
- whether they are logged, streamed, or ignored
Those decisions belong to the host environment.
Events are created at well-defined points during plan execution:
- Run-level events (
IdLE.Run.*) when a plan starts and finishes - Step-level events (
IdLE.Step.*,IdLE.OnFailure.*) when a step starts, completes, fails or is skipped - Domain events emitted by steps and providers (for example
IdLE.Step.DirectorySync.Completed) - Workflow-defined events from
PreconditionEventand theIdLE.Step.EmitEventstep
All events share a common intent:
describe what happened, not how it should be presented.
Every event is an object with PSTypeName = 'IdLE.Event':
| Property | Description |
|---|---|
TimestampUtc |
UTC timestamp. |
Type |
What happened (see Event types). |
Level |
How severe it is: Information, Warning or Error. |
Message |
Human-readable message. Do not parse it; use Type and Data. |
CorrelationId |
Correlation ID of the request. |
Actor |
Actor of the request. |
StepName |
Name of the step (empty for run-level events). |
Data |
Optional hashtable with structured details (redacted at output boundaries). |
Steps and providers write events through the execution context:
$Context.EventSink.WriteEvent(Type, Message, StepName, Data[, Level])Level is optional and defaults to Information.
Type names the event; Level carries the severity. Sinks filter on both (for example: alert on
Level = 'Error', audit on IdLE.Provider.AD.AttributeChanged).
| Emitted by | Format | Example |
|---|---|---|
| IdLE (engine, first-party steps and providers) | IdLE.<Area>.<Event> |
IdLE.Step.Failed, IdLE.Provider.AD.AttributeChanged |
| Extensions (third-party steps and providers) | <Owner>.IdLE.<Area>.<Event> |
Contoso.IdLE.Hr.ManagerSynced |
Workflows (PreconditionEvent.Type, EmitEvent With.Type) |
free, but not IdLE.* |
Contoso.ManualActionRequired |
Rules:
IdLE.*is reserved for events emitted by IdLE. Workflow-defined event types starting withIdLE.are rejected (ReservedNamespace); see Step type names for the namespace scheme.Information,Warning,ErrorandCustomare not valid event types (InvalidEventType). Use a descriptive type and set the severity withLevel.- Event types and their
Datafields listed below are a contract.Messagetexts are not.
| Type | Level | Data |
|---|---|---|
IdLE.Run.Started |
Information | CorrelationId, Actor, StepCount |
IdLE.Run.Completed |
Information; Warning if Blocked; Error if Failed |
Status, StepCount |
IdLE.Step.Started |
Information | StepType, Index |
IdLE.Step.Completed |
Information | StepType, Index |
IdLE.Step.Failed |
Error | StepType, Index, Error |
IdLE.Step.Blocked |
Warning | StepType, Index |
IdLE.Step.NotApplicable |
Information | StepType, Index |
IdLE.Step.PreconditionFailed |
Warning | StepType, Index, OnPreconditionFalse |
IdLE.Step.Retrying |
Warning | attempt, maxAttempts, delayMs, errorType, message |
IdLE.OnFailure.Started |
Information | OnFailureStepCount |
IdLE.OnFailure.Completed |
Information; Warning if PartiallyFailed |
Status, StepCount |
IdLE.OnFailure.StepStarted |
Information | StepType, Index |
IdLE.OnFailure.StepCompleted |
Information | StepType, Index |
IdLE.OnFailure.StepFailed |
Error | StepType, Index, Error |
IdLE.OnFailure.StepNotApplicable |
Information | StepType, Index |
IdLE.Run.Completed is always the last event of a run.
| Type | Level | Data |
|---|---|---|
IdLE.Step.EmitEvent.Emitted |
With.Level (default Information) |
StepType |
IdLE.Step.DirectorySync.Triggered |
Information | PolicyType, ComputerName |
IdLE.Step.DirectorySync.Waiting |
Information | TimeoutSeconds, PollIntervalSeconds |
IdLE.Step.DirectorySync.Polled |
Information | Attempt, State, InProgress, ElapsedSeconds |
IdLE.Step.DirectorySync.Completed |
Information | Attempts, ElapsedSeconds (waited) or PolicyType (not waited) |
IdLE.Step.DirectorySync.Failed |
Error | TimeoutSeconds, ElapsedSeconds, LastKnownState (timeout) or Error |
IdLE.Step.PruneEntitlements.Planned |
Information | Kind, KeepCount, PruneCount |
IdLE.Step.PruneEntitlements.EntitlementRevoked |
Information | Kind, EntitlementId |
IdLE.Step.PruneEntitlements.EntitlementSkipped |
Warning | Kind, EntitlementId, Reason |
IdLE.Step.PruneEntitlements.KeepGranted |
Information | Kind, EntitlementId |
IdLE.Step.PruneEntitlements.KeepGrantFailed |
Warning | Kind, EntitlementId, Reason |
IdLE.Step.EmitEvent emits IdLE.Step.EmitEvent.Emitted unless the workflow sets With.Type.
Providers emit events only when the host passes an event sink to the provider.
| Type | Level | Data |
|---|---|---|
IdLE.Provider.AD.AttributesRequested |
Information | IdentityKey, Requested |
IdLE.Provider.AD.AttributeChanged |
Information | IdentityKey, AttributeName, OldValue, NewValue |
IdLE.Provider.ExchangeOnline.PermissionsEvaluated |
Information | MailboxSmtp, Right, CurrentUsers |
IdLE.Provider.ExchangeOnline.PermissionChanging |
Information | MailboxSmtp, Right, User, Action |
IdLE.Provider.ExchangeOnline.PermissionsEnsured |
Information | MailboxSmtp, Changed |
Event types were renamed in one step without aliases:
| Old type | New type |
|---|---|
RunStarted, RunCompleted |
IdLE.Run.Started, IdLE.Run.Completed |
StepStarted, StepCompleted, StepFailed, StepBlocked, StepNotApplicable, StepPreconditionFailed, StepRetrying |
IdLE.Step.Started, .Completed, .Failed, .Blocked, .NotApplicable, .PreconditionFailed, .Retrying |
OnFailureStarted, OnFailureCompleted |
IdLE.OnFailure.Started, IdLE.OnFailure.Completed |
OnFailureStepStarted, OnFailureStepCompleted, OnFailureStepFailed, OnFailureStepNotApplicable |
IdLE.OnFailure.StepStarted, .StepCompleted, .StepFailed, .StepNotApplicable |
DirectorySyncTriggered, DirectorySyncWaiting, DirectorySyncPoll, DirectorySyncCompleted, DirectorySyncFailed |
IdLE.Step.DirectorySync.Triggered, .Waiting, .Polled, .Completed, .Failed |
Information / Warning (PruneEntitlements) |
IdLE.Step.PruneEntitlements.Planned, .EntitlementRevoked, .EntitlementSkipped, .KeepGranted, .KeepGrantFailed |
Custom (EmitEvent) |
IdLE.Step.EmitEvent.Emitted or the workflow's With.Type |
Provider.AD.CreateIdentity.AttributesRequested, Provider.AD.EnsureAttribute.AttributeChanged |
IdLE.Provider.AD.AttributesRequested, IdLE.Provider.AD.AttributeChanged |
Provider.ExchangeOnline.Permissions.Evaluated, .Applying, .Result |
IdLE.Provider.ExchangeOnline.PermissionsEvaluated, .PermissionChanging, .PermissionsEnsured |
During execution, events are buffered inside the execution result.
This means:
- The engine can run in completely headless environments
- No output is produced unless the host explicitly consumes events
- Events are always available after execution for inspection
Buffering is the default because it keeps the core:
- deterministic
- testable
- independent of runtime context
Hosts may provide an event sink to receive events as they happen.
The engine expects an object with a WriteEvent(event) method.
If present, the engine forwards each event to that sink in addition to buffering
events in the execution result.
This enables patterns such as:
- forward events to a central logging system
- push events to a message bus
- render progress updates in an interactive host
The engine still does not assume anything about formatting, persistence, or transport.
Different hosts consume events differently:
- Collect all events
- Render them after execution in a human-readable form
- Optionally summarize counts or highlight failures
The repository demo runner is an example of this pattern.
- Inspect execution status
- Fail the pipeline if an event with
Level = 'Error'exists (for exampleIdLE.Step.Failed) - Optionally archive event output as build artifacts
- Execute plans headlessly
- Forward buffered events to logging, tracing, or messaging systems
- Decide independently whether events are streamed or processed asynchronously
Clear responsibility boundaries are essential:
-
Engine
- Creates events at defined lifecycle points
- Buffers events in execution results
- Does not format, log, or persist events
-
Steps
- May emit custom, domain-specific events
- Must not assume how or where events are displayed
-
Host
- Decides how events are consumed
- May format, log, store, or forward events
- May ignore events entirely
This separation ensures that IdLE remains portable and reusable across environments.
Events are a primary observability surface and therefore a common place where sensitive values can accidentally leak.
Guidelines:
- Do not emit secrets in
Event.Data(tokens, passwords, client secrets, API keys, certificates). - Prefer references (for example: identity IDs, step names, correlation IDs) over raw payloads.
- The engine applies redaction at output boundaries (buffered events and host sinks) for
common sensitive key names (for example:
password,token,secret,apiKey). Redaction is a safety net, not a design strategy. - When acquiring authentication sessions, use
Providers.AuthSessionBrokerviaContext.AcquireAuthSession(Name, Options). Auth session options are a data-only boundary and reject ScriptBlocks.
Events are not written to the console automatically. If a host does not explicitly render or process events, they remain buffered only.
This is intentional.
Events should not be used as a replacement for structured logging. They represent execution semantics, not debug traces.
If detailed diagnostics are required, hosts should integrate their own logging mechanisms alongside IdLE execution.
The engine must never:
- write directly to the console
- depend on a logging framework
- assume interactive execution
Violating this separation would break testability and portability.