This file holds what is particular to FerroFED: which release is supported, until when security fixes are published, where to report a vulnerability in FerroFED, and the versions withdrawn. The vulnerability-handling policy of Cadasto B.V., the manufacturer of every FerroHEALTH product, is on the family book's Security page: what happens after a report, how a fix and its advisory reach you, how to hear of an update, and what the manufacturer reports to the authorities. This page is not legal advice.

One FerroFED release is the source tag, the binary tarballs and the gateway and console images of one version. Cadasto B.V. places each tagged release on the market as one product under Regulation (EU) 2024/2847, the Cyber Resilience Act (CRA), and as an EHR system under Regulation (EU) 2025/327 on the European Health Data Space (EHDS) (regulatory status).

Supported versions

Only the newest release is supported. When a new release is published, every earlier release stops receiving fixes: there are no maintenance branches, no long-term-support line and no backports. If you are not on the newest release, upgrade; upgrading is free. Under the Cyber Resilience Act, Cadasto B.V. commits to keep publishing security fixes for at least five years after each release (Art 13(8)) and ships them only in the newest release (Art 13(10)).

Artifact Supported version Where fixes ship
The ferrofed binary (release tarballs) the newest published release the newest release
The gateway and console container images the newest published release the newest release
  • The five years: Cadasto B.V. keeps publishing security fixes, in new releases, for at least five years after each release is placed on the market, the minimum Art 13(8), third subparagraph, sets. Each end date in the table below is computed from that rule: it is the date until which Cadasto B.V. commits to keep publishing fixed releases, and a release itself is supported only while it is the newest. If Cadasto B.V. sets a longer period, this page states it. The matters Art 13(8) names, and how each was taken into account, are recorded in the book's basis of the five years (Annex VII, point 4).
  • Where fixes ship: a security fix ships in a new release, a patch release with no feature changes in it, so the update is provided separately from functionality updates (Annex I Part II(2)). Art 13(10) lets Cadasto B.V. ship it only in the newest release, provided a user of an earlier release gets the newest one free of charge and with no added cost to adjust the environment it runs in. Every release is published under the same licence terms as the one before it, and a published release is never changed, so a user of an older release upgrades to the newest release to get the fix.
  • Updates stay available: a published release, its tag and its image digest are never deleted (docs/release.md).
  • An older release: a release that is not the newest receives no fix. The releases page keeps every version available, and running an older one leaves each vulnerability fixed in a later release unfixed in it (Art 13(11)). From v0.0.10 on, the gateway knows its own end date from its build, names it in the startup banner and in OPTIONS {base}/, and once the date has passed says so in the banner, at start in its log and in ferrofed config check (Art 13(19)).

Art 13(8) binds the releases placed on the market from 11 December 2027 (Art 69(2), Art 71(2)). Cadasto B.V. gives the releases placed before that date the same commitment. A pre-release (a tag with a suffix, such as v0.0.2-rc.1) rehearses the release lane and has no support period. main is development code that is not supplied for use.

From v0.0.10 on, the release notes of each release open with its end date, and scripts/release/changelog.sh --assemble adds its row here when the release is cut (docs/release.md). The notes of an earlier release cannot be changed, so its end date is stated here and in the copy of this table on the book's CRA information to the user, which scripts/checks/support-periods.sh holds to this one.

Release Released Fixes published until
v0.0.1 2026-10-01 2031-10-01
v0.0.3 2026-10-02 2031-10-02
v0.0.6 2026-10-03 2031-10-03
v0.0.7 2026-10-03 2031-10-03
v0.0.8 2026-10-04 2031-10-04
v0.0.9 2026-10-05 2031-10-05
v0.0.10 2026-10-15 2031-10-15
v0.0.11 2026-10-16 2031-10-16

A withdrawn release gets no fix of its own either. It is listed under Withdrawn versions below, and its advisory names the release to move to.

Reporting a vulnerability

Do not open a public issue for a security vulnerability. Report it privately through GitHub's private vulnerability reporting: https://github.com/FerroHEALTH/FerroFED/security/advisories/new. You will get an acknowledgement within seven days. If that window passes with no response, public disclosure to protect other users is your call. Without a GitHub account, use the manufacturer's email route on the family book's Security page.

A patient identifier reaching a node is a vulnerability in FerroFED: the gateway's central safety property is that no request it composes for a node carries one. Report it here, privately.

If you have evidence that someone is exploiting the vulnerability, say so in the report: an actively exploited vulnerability starts the 24-hour clock below.

Actively exploited vulnerabilities and severe incidents

CRA Art 14 covers every FerroFED release. Cadasto B.V. notifies an actively exploited vulnerability or a severe incident through ENISA's single reporting platform, with an early warning within 24 hours, as the family book's Security page describes. FerroFED tells its users through a GitHub security advisory on this repository, with a direct message to every user Cadasto B.V. knows from a contract. FerroFED's own procedure is on the book's Complaints and incidents page and in docs/post-market.md.

Serious incidents and non-conforming versions

The EHDS adds duties of its own. A vulnerability that harmed a person, or could, may be a serious incident, which the manufacturer reports to the market surveillance authorities within three days of becoming aware of it (EHDS Art 44(7)). This report is separate from the CRA notifications above: one event can need both, and neither stands in for the other. Report it as above, and also write to info@cadasto.com with "FerroFED incident" in the subject. A vulnerability that made a version non-conforming is entered in the register of non-conforming versions once its advisory is published. The procedures are on the book's Complaints and incidents page and in docs/post-market.md.

Withdrawn versions

A version Cadasto B.V. found not to conform and withdrew (Regulation (EU) 2025/327 Art 30(1)(i)) stays listed here. It is not supported, and its advisory says which version to move to. A published release cannot be changed or deleted, so the release, its tag and its image digest remain; the <major>.<minor> and latest image tags move to the replacement. scripts/release/withdraw.sh adds the row, as docs/release.md describes.

Version Withdrawn Finding Advisory

There aren't any published security advisories