S2 changelog: one sensor holds the charging efficiency of all operation modes - #288
Merged
Merged
Conversation
… all operation modes As asked in the review of #283. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01CcpawsJs74cSwFLXkz7ZwW Signed-off-by: F.N. Claessen <claessen@seita.nl>
Coverage Report for CI Build 42681587466Warning No base build found for commit Coverage: 95.943%Details
Uncovered ChangesNo uncovered changes found. Coverage RegressionsRequires a base build to compare against. How to fix this → Coverage Stats
💛 - Coveralls |
Flix6x
commented
Nov 9, 2026
| * ``FRBCSimple`` takes a ``fill_level_scale`` (default 1). Every fill level and fill rate sent to FlexMeasures is multiplied by it: the state of charge, the flex model, the fill-level band, the fill rate, the usage forecast and the storage efficiency. Translating a schedule into instructions keeps the resource manager's own units, because it matches fill levels against the operation modes, which are stated in those units. A scale of zero or below is refused. ``FRBCSimple`` also takes a ``power_unit`` (default ``W``), which an actuator's power is converted into and posted in [`#236 <https://github.com/FlexMeasures/flexmeasures-client/pull/236>`__, `#244 <https://github.com/FlexMeasures/flexmeasures-client/pull/244>`__, `#245 <https://github.com/FlexMeasures/flexmeasures-client/pull/245>`__, `#252 <https://github.com/FlexMeasures/flexmeasures-client/pull/252>`__] | ||
| * ``FRBCSimple`` takes a ``hard_bound_factor`` (default 1.5). It sets how far above the declared fill-level range a schedule's hard upper bound lies. If a schedule starts from a state of charge above that bound, the bound is raised to include it. A factor below 1 is refused: FlexMeasures clips the band to the hard bounds, so a hard upper bound inside the declared range would narrow the band to something the resource manager never asked for [`#245 <https://github.com/FlexMeasures/flexmeasures-client/pull/245>`__] | ||
| * ``FRBCSimple`` can take the actuator's charging efficiency into account. Give it the new ``charging_efficiency_sensor_id``: it records there what the operation modes say about converting drawn power into stored energy, and requests a schedule with it as ``charging-efficiency``. For a heat pump, this ratio is its coefficient of performance. Without it, the scheduler assumes power converts into stored energy one to one, and plans to reach fill-level targets at a power the actuator cannot deliver. | ||
| * ``FRBCSimple`` can take the actuator's charging efficiency into account. Give it the new ``charging_efficiency_sensor_id``: before each schedule request, it records there one efficiency for all operation modes, over the window of the schedule, from what they say about converting drawn power into stored energy, and requests the schedule with it as ``charging-efficiency``. For a heat pump, this ratio is its coefficient of performance. Without it, the scheduler assumes power converts into stored energy one to one, and plans to reach fill-level targets at a power the actuator cannot deliver. |
Member
Author
There was a problem hiding this comment.
Split into short sentences in 8299241: what the efficiency is first, then what the handler does with it. In the sub-bullet, the shared sensor now leads, and the fill-level case follows the choice between modes.
…nces Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01CcpawsJs74cSwFLXkz7ZwW Signed-off-by: F.N. Claessen <claessen@seita.nl>
…ensor Signed-off-by: F.N. Claessen <claessen@seita.nl>
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Follows up on a review comment on #283, which asked to clarify how the efficiencies of different operation modes end up on a single sensor.
What
The changelog entry for
charging_efficiency_sensor_idnow says:Changelog only; no code changes.
🤖 Generated with Claude Code
https://claude.ai/code/session_01CcpawsJs74cSwFLXkz7ZwW