S2 states leakage as a rate per fill-level range. It was planned as a storage efficiency, which FlexMeasures takes as a share of the stock, so the storage leaked in proportion to how full it was, exact at one fill level only. The leakage rate of the range the storage starts in is now added to the usage, over the whole window, and sent with the schedule request. With a usage correction, the correction covers usage and leakage together, so an empty storage's leakage can be taken away like any other forced usage. The leakage sensor records that rate, in the fill-rate unit, and the site sensor is now called "leakage". It needs FlexMeasures v0.23.0, which takes a usage with the request; an older server is planned without leakage. As asked in the review of #283. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01CcpawsJs74cSwFLXkz7ZwW Signed-off-by: F.N. Claessen <claessen@seita.nl>
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01CcpawsJs74cSwFLXkz7ZwW Signed-off-by: F.N. Claessen <claessen@seita.nl>
Coverage Report for CI Build 42683851519Warning No base build found for commit Coverage: 96.203%Details
Uncovered ChangesNo uncovered changes found. Coverage RegressionsRequires a base build to compare against. How to fix this → Coverage Stats
💛 - Coveralls |
| - A fill-level target profile is recorded on the minima and maxima sensors, if both are given. It is recorded on the handler's ``resolution`` steps, starting from the step its start falls in. It is kept inside the declared fill-level range: a target past either end, such as a night setback below the range, is cut back to the range, and a target band wholly outside the range is recorded at its nearest end, with a warning. If one of the two bounds cannot be recorded, this is logged and the other is still recorded. | ||
| - A usage forecast is recorded in ``<energy_unit>/s``. A negative expected usage, which S2 allows, is recorded as stated. Without a usage correction (see below), a schedule request carries the latest forecast without its negative values, since FlexMeasures would plan them as a gain the storage cannot refuse. A FlexMeasures server before v0.23.0 only plans with what is recorded, so there a negative expected usage is recorded as zero, with a warning [`#286 <https://github.com/FlexMeasures/flexmeasures-client/pull/286>`__]. | ||
| - A leakage behaviour is recorded as a storage efficiency, each time a schedule is requested (see Changed). | ||
| - A leakage behaviour is recorded as the leakage rate it states, in ``<energy_unit>/s``, each time a schedule is requested (see Changed) [`#289 <https://github.com/FlexMeasures/flexmeasures-client/pull/289>`__]. |
There was a problem hiding this comment.
kWh/s would be a terrible unit to read typical residential values in (in FM UI and logs). I would pick a better FM sensor unit.
There was a problem hiding this comment.
Agreed. Rates of fill level (the fill rate, the usage forecast and the leakage) are now recorded in a power unit instead of per second. There is a new fill_rate_unit setting, like energy_unit and power_unit: W (the default), kW or MW. The site creates these three sensors in W, so the example's leakage reads 62.5 W instead of 1.7e-5 kWh/s (ca1bfb7, 83fbf23; changelog updated). An existing site keeps the fill rate and usage forecast sensors it already has in kWh/s; FlexMeasures converts the posted values into them.
There was a problem hiding this comment.
Applied to every sensor the CEM sets up, in 3b18345: power, measured-power and usage correction are now in W as well, so every power and rate of fill level a new site gets is in W, the handler's default. Energy and fill levels stay in kWh, and prices per kWh. A larger site, such as one with charge points, can pass its own sensors and set power_unit and fill_rate_unit. A site created before this keeps its sensors, and the CEM now logs a warning for each one in a different unit than a new site would get.
There was a problem hiding this comment.
Dropped the warning about a kept sensor in another unit again (f2d9cca): FlexMeasures converts what is posted into the sensor's own unit, so there is nothing to warn about.
S2 states these rates per second, so in kWh/s a heat buffer's leakage of some tens of watts reads about 0.00001. They are now recorded in the power unit that goes with the energy unit (kW for kWh, W for J and Wh, MW for MJ and MWh), and the site's fill rate, usage forecast and leakage sensors are created in kW. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01CcpawsJs74cSwFLXkz7ZwW Signed-off-by: F.N. Claessen <claessen@seita.nl>
Like the energy and power units, the unit that rates of fill level are recorded in is the deployment's to set: W (the default), kW or MW. Watts read a residential heat buffer's leakage of some tens of watts as such; the site's fill rate, usage forecast and leakage sensors are created in W. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01CcpawsJs74cSwFLXkz7ZwW Signed-off-by: F.N. Claessen <claessen@seita.nl>
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01CcpawsJs74cSwFLXkz7ZwW Signed-off-by: F.N. Claessen <claessen@seita.nl>
Every power and rate of fill level the CEM sets up is now in W, the handler's default: power, measured-power and usage correction joined fill rate, usage forecast and leakage. Watts read a residential site's small powers as such; a larger site passes its own sensors. An existing site keeps its sensors, and one in another unit than a new site would get is logged as a warning. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01CcpawsJs74cSwFLXkz7ZwW Signed-off-by: F.N. Claessen <claessen@seita.nl>
FlexMeasures converts what is posted into a sensor's own unit, so an older site's sensor in kW is a valid choice, not a fault. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01CcpawsJs74cSwFLXkz7ZwW Signed-off-by: F.N. Claessen <claessen@seita.nl>
Stacked on #286 (base
feat/s2-usage-correction). Merge #286 first.Follows up on a review comment on #283: "If S2 states a rate, shouldn't this then be better modelled as an extra component in the soc-usage list?"
Why
S2 states leakage as a rate per fill-level range, in fill-level units per second.
FRBCSimpleplanned it as astorage-efficiency, which FlexMeasures takes as a share of the stock. So the plan had the storage leak in proportion to how full it was, which was exact at one fill level only, and S2 does not say leakage is proportional.What
soc-usage, constant over the schedule window, and sent with the request. Nostorage-efficiencyis sent any more.leakage(kWh/s) instead ofstorage efficiency(%), inFRBC_SITE_SENSORSand the example server.Caveats
Evidence
fill_level_scale, recording the rate (and not again for the same window), planning despite a failed recording, an older server, leakage without a usage forecast or its sensor, the correction covering both, clipping both together without a correction, and the correction price's storage term. Each fails when its behaviour is broken.🤖 Generated with Claude Code
https://claude.ai/code/session_01CcpawsJs74cSwFLXkz7ZwW