croak.crystals.depth_points asks for ceil(φ) + 3 Gauss–Legendre depth nodes, with φ = max|Δk|·L/2 over the grid's component pairs, and the forward models refuse fewer (depth_points at 6800603, check_medium). The rule is safe but generous at large φ. The smallest count whose error stays below 10⁻⁶·L for every φ′ in [0, φ] (the accuracy the docstring promises):
φ (rad)
nodes needed
ceil(φ) + 3
20
18
23
40
30
43
60
41
63
120
74
123
250
142
253
Found by the review of #31 and reproduced independently (a NumPy scan of ∫₀¹ e^{−2iφ′u} du against the closed form, φ′ sampled at 2001 points in [0, φ]; run, 2026-11-17). Asymptotically Gauss–Legendre resolves an oscillation of half-phase φ with about eφ/4 ≈ 0.68φ nodes, consistent with the table.
Why it matters
The forward map and the hand adjoint cost scale linearly with the node count. A 1.5 fs grid with 500 µm of BBO crossed at 5.7° asks for about 260 nodes where about 145 would do, so every solver iteration pays about 1.8×. Because check_medium refuses counts below the rule, a user cannot opt out.
To do
Choose a tighter rule of the form a·φ + b(φ) (for example about φ/2 plus a slowly growing margin), and check it against the scan above extended to φ = 500.
Extend test_depth_rule_resolves_the_oscillation (tests/test_crystals.py) upward in φ (to at least 250) so it pins the new rule, including the worst φ′ below each φ, not only φ itself.
Update the depth_points docstring and the depth-resolution paragraph of docs/explanation/forward_model.md.
Must not change: the 10⁻⁶·L accuracy guarantee per pair; depth_points returning 1 at zero thickness; the arms' drift κ(ω₁−ω₂) being part of φ (added in Model SHG in a Type I crystal in the forward models #31 after the review).
Done when
The extended rule test passes for every φ in its range, the crystal forward-model tests (tests/test_forward_crystal.py) still agree with the exact pair sum at their tolerances, and the node count for the 1.5 fs / 500 µm / 5.7° case drops by at least 1.5×.
Follow-up to #31, part of #24. Drafted with Claude Code.