Propose updating gravity shear tab DS3 to SC3. DS3 has a description "Complete separation of shear tab, close to complete loss of vertical load resistance", which closely matches Safety Class 3 description of "severe damage that compromises both lateral and vertical load carrying capacity of the component." - Updated B1031\.00\w+ ds_index 3 to safety_class 3
zsarnoczay
approved these changes
Sep 10, 2026
zsarnoczay
left a comment
Collaborator
There was a problem hiding this comment.
Thank you, Huy; looks good to me.
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Summary of changes
damage_state_attribute_mapping.csvDetail and Rationale
This proposal affects gravity shear tab component (B1031.00\w+).
The component's DS3 has a description "Complete separation of shear tab, close to complete loss of vertical load resistance", which closely matches Safety Class 3 description of "severe damage that compromises both lateral and vertical load carrying capacity of the component."
This damage state is documented in the following testing references, which were used to develop the FEMA P-58 fragility database. Therein, at the median drift specified for DS3 (0.11), experimental testing descriptions consistently reported complete "fracture" of the tab. This would likely correspond with a significant loss in vertical load carrying capacity.
Deierlein, G., & Victorsson, V. K. (2008). Fragility Curves for Components of Steel SMF Systems, FEMA P-58/BD-3.8.3. Federal Emergency Management Agency.
Liu, J., & Astaneh-Asl, A. (2000). Cyclic testing of simple connections including effects of slab. Journal of Structural Engineering, 126(1), 32–39. https://doi.org/10.1061/(ASCE)0733-9445(2000)126:1(32)
This change was previously applied during the development of the 2026 NEHRP Seismic Provisions Appendix A, where the component in its updated state was used during the prequalification of several lateral force-resisting systems.
Pham, H. G., Blowes, K., Molina Hutt, C., Zimmerman, R. B., Almeter, E., Welch, D. P., DeBock, J. D., & Haselton, C. B. (2026). Functional Recovery Design Parameters for Five Additional Seismic Force-Resisting Systems in the 2026 NEHRP Recommended Provisions. Earthquake Spectra. (in review)
Results
Passed 18/18 integration tests.
This DS/SC upgrade is likely to occur at an EDP that would already trigger red-tagging via other global consequences (residual drift, e.g.). Therefore, no major effects to outcomes is expected.