A dedicated XRD data processing and Rietveld structure refinement tool for lithium iron phosphate (LiFePO4, olivine type, Pnma).
A member of the PolyXRD family. It opens to a single interface: pattern on the left + sample conditions and built-in structure below the pattern, identification and refinement results on the right; after importing a pattern it first determines whether it is LiFePO4, and stops if not, allowing CIF-based refinement only when it is.
Rietveld fitting can force a structure that "does not belong to this pattern" onto it — parameters still converge, Rwp still looks fine, but the resulting unit-cell parameters have no physical meaning. So in PolyXRD LFP, identification is a gate, not a "suggestion":
- Import pattern → automatic identification → if not LiFePO4, a pop-up explains why not and locks the refine button;
- Refinement unlocks only after identification passes, and the refinement starting point (unit-cell pre-fit, zero point) comes from the identification-stage match.
Identification uses four interpretable criteria, all of which must be satisfied to pass (thresholds frozen in lfp/core/identify.py):
| Criterion | Meaning | Threshold |
|---|---|---|
| Coverage coverage | Fraction of measured-peak intensity explained by LFP reference peaks (weighted by calculated relative intensity) | ≥ 70 % |
| Top-3 strongest top3 | The 3 strongest calculated lines within the data range must each have a corresponding measured peak | 3 / 3 |
| Unexplained intensity unexplained | Fraction of measured-peak intensity that cannot be assigned to LFP (Kα1/Kα2 satellite peaks exempt) | ≤ 35 % |
| Model adequacy model_ok | After removing zero point and isotropic expansion/contraction, paired-peak position residual RMS ≤ 0.45× position tolerance | ≤ 45 % |
The first three only count "is there a peak, is the intensity enough" and are insensitive to systematic peak-position shifts; the fourth makes up for this: if the sample has obvious anisotropic deformation (or an overlapping second phase), the two-parameter model cannot suppress the position deviation, and discipline requires rejection rather than forcing a coverage figure to pass.
The identification result writes "which criterion failed" directly into the panel and pop-up, so users do not have to guess the reason from a pile of passing numbers.
Left: pattern processing (all non-destructive, one click restores the original pattern)
| Operation | Method |
|---|---|
| Smoothing | Savitzky–Golay (window/order adjustable, window auto-set to odd) |
| Background subtraction | SNIP iterative peak clipping / polynomial fitting / endpoint linear |
| Kα2 removal | Rachinger stripping (recursion direction low angle → high angle, selectable target and I(α2)/I(α1)) |
| Peak finding | find_peaks localization + per-peak pseudo-Voigt fitting + linear background, with a quality gate and position de-duplication |
| View | Toggles between "Pattern" and "Fit result" states; the fit state shows measured / calculated / background / difference curves and Bragg position ticks |
Below the pattern: structure model
- Built-in LiFePO4 CIF (
lfp/data/lfp.cif, Pnma, No. 62, Z = 4); - Custom CIF import (automatically reads space group, unit cell, atomic coordinates, formula weight / mineral species name);
- Displayed side by side with "Sample and measurement conditions"; the identification card, symmetry card (crystal system / space group / point group / Laue group / Bravais lattice) and refinement panel are in the right column.
Refinement (Rietveld full-pattern fitting, variable-projection least squares: the linear layer solves the structure-factor scale and background coefficients analytically,
the non-linear layer uses scipy.optimize.least_squares)
Refinable parameters can be checked off: unit cell a/b/c, zero point, crystallite size (Scherrer), microstrain (Wilson), low-angle asymmetry, March–Dollase preferred orientation (020), instrumental broadening U/V/W, overall temperature factor B; the peak-shape η and the number of background terms are optimized along with the configuration.
After refinement it gives: unit cell a/b/c and α/β/γ, volume, crystal system, space group (with ITA number), point group (with Schönflies symbol), Laue group, Bravais lattice, crystallite size, microstrain, and
- Rwp / Rp / Rexp / χ² / GOF: following the GSAS-II convention (background included,
w = 1/σ²,σ = √max(y, 1),Rexp = 100·√((N−P)/Σw·y_o²),GOF = Rwp/Rexp); - R_Bragg: profile-partitioned, overlapping peaks apportioned by peak-height amplitude, converted to "counts·degrees".
The absolute value of Rwp is strongly correlated with counting statistics, so the UI also gives a GOF interpretation tier: when Rwp is high but GOF ≤ 1.2 it hints "the fit is adequate; the high Rwp is limited by counting statistics", rather than simply saying "poor fit".
Export: HTML report (embedded fit plot, identification evidence chain, refinement parameter list, unit-cell/symmetry/microstructure table, Bragg table), result-summary CSV, measured/calculated/difference/background CSV, Bragg table CSV, peak table CSV, fit plot PNG.
:: Run from source (requires numpy / scipy / matplotlib / PySide6)
python -m lfp.gui
:: Package as a single-file exe (artifact dist\PolyXRD-LFP-vX.Y.Z.exe)
build_exe.batpython -m pytest tests\ -q :: full suite (79 tests)
python -m pytest tests\ -q -m "not slow" :: skip time-consuming cases
python tools\diag_identify.py :: identification regression table (all thresholds are set by this table)Real-instrument pattern regression needs to point to the export directory (when it does not exist, the related cases are skipped automatically):
set POLYXRD_LFP_DATA=D:\Project\XRD\XRData\smz geshiTest files are documentation: tests/test_identify.py pins the identification discipline with both positive and negative cases
("what should pass must pass, what should not pass must never pass"), test_rfactors.py pins the R-factor conventions,
and test_processing.py pins the direction and idempotence of Kα2 stripping.
- Identification targets single-phase LiFePO4; patterns with an obvious second phase (FePO4, carbon-coating by-products, etc.) are rejected — this is a design choice (better to miss and let the user override manually than to misidentify and refine all the way);
- The peak shape is pseudo-Voigt + Caglioti, with no instrument calibration; without a standard sample it is recommended to release only one of U/V/W;
- The temperature factor B is strongly correlated with crystallite size, off by default, and prone to divergence when enabled;
- Instrument effects such as Kβ residue, Ni filter absorption and fluorescence background are not handled (avoid them first via pattern processing).
lfp/
core/ Diffraction kernel: io / processing / peaks / identify / symmetry
profile/ CIF parsing, unit cell and reflection table, peak shape, structure factor
refine/ Linear layer, non-linear layer, R factors, R_Bragg, public API
gui/ Single-window UI: main_window / panels / canvas / dialogs / report / exports
data/lfp.cif Built-in LiFePO4 structure
i18n/ Chinese-English bilingual copy (key sets must match, missing keys shown as ⟪key⟫)
resources/ Brand assets (icon / logo / splash / hero, generated by tools/build_artwork.py)
tools/ build_artwork.py (brand images), diag_identify.py (identification regression table)
tests/ pytest (real-pattern regression needs POLYXRD_LFP_DATA)
docs/ METHOD.md (algorithms and conventions), VALIDATION_v1.0.0.md (validation record), evidence/
| Version | Changes |
|---|---|
| 1.1.0 | Layout adjustment: sample and measurement conditions, structure model moved below the pattern side by side; right column keeps only identification / refinement / results, no longer crowded horizontally; fixed a display defect where card group titles (unit-cell parameters, measurement conditions, etc.) were pressed onto the first data row; after a language switch the structure and identification cards are re-rendered in the current language |
| 1.0.0 | First release: trilingual (Chinese / Japanese / English), identification gate, Rietveld refinement, internal evaluation build / installed registered edition dual editions |
- License: see LICENSE / LICENSE-CN
- Copyright: © 2026 PolyXRD Team
- Contact: sshztx@outlook.com · https://github.com/PolyXRD