Skip to content

widthSOL_eich, widthSOL_sieglin: aspect ratio from the minor radius - #329

Merged
tomneiser merged 1 commit into
masterfrom
fix/eich-minor-radius
Nov 16, 2026
Merged

tomneiser merged 1 commit into
masterfrom
fix/eich-minor-radius

Conversation

@tomneiser

Copy link
Copy Markdown
Member

widthSOL_eich(eqt, Psol) and widthSOL_sieglin(eqt, cp1d, core_sources) pass the full midplane width of the last closed surface as the minor radius of the Eich scaling:

a = (eqt1d.r_outboard[end] .- eqt1d.r_inboard[end])

The scaling (T. Eich et al., Nucl. Fusion 53 (2013) 093031, table 3, regression #15) is

λq [mm] = 1.35 Psol^-0.02 Rgeo^0.04 Bpol^-0.92 (a/Rgeo)^0.42

with a the minor radius (table 1 lists a = 0.95 m for JET, 0.51 m for DIII-D, 2.0 m for ITER) and Bpol the poloidal field at the outer midplane separatrix. So λq came out 2^0.42 = 1.34 times too large. This PR divides the width by two, as boundary.minor_radius and the rest of IMAS do.

Check against the paper

With the ITER row of table 1 (Rgeo = 6.2 m, a = 2.0 m, Bpol = 1.185 T, Psol = 100 MW) widthSOL_eich(R0, a, Bpol_omp, Psol) gives 0.70 mm; the paper quotes λq,ITER = 0.73 mm for regression #15. With a = 4.0 m it gives 0.94 mm.

Bpol_omp(eqt) already is the paper's definition of Bpol, so nothing changes there. The line dates from the first version of the function (eb75b766, 2022), where the same a also went into the average poloidal field Bpol(a, κ, Ip).

Effect

On FUSE.init of ITER (from scalars), D3D and FPP, before → after:

ITER D3D FPP
widthSOL_eich(dd) [mm] 0.895 → 0.669 3.46 → 2.58 0.914 → 0.683
widthSOL_sieglin(dd) [mm] 3.74 → 3.52 5.90 → 5.02 4.71 → 4.48
q_pol_omp_eich(dd) [MW/m²] 2692 → 3602 126 → 168 1645 → 2200
peak particle heat flux on the wall, default q(r) of mesher_heat_flux [MW/m²] 343 → 458 25.7 → 34.3 340 → 454

Everything that takes its λq from widthSOL_eich moves with it: the λq entry of extract, the default q(r) of mesher_heat_flux, and in FUSE the wetted areas of ActorDivertors (× 0.75) and the default λq of ActorSOLBox (twice the Eich value; ITER upstream Te 263 → 285 eV).

Tests

New sol.jl testset in test/runtests_smoke.jl: the scaling against the paper's ITER value, and the time-slice and dd methods of widthSOL_eich and widthSOL_sieglin against the scaling evaluated with the minor radius. runtests_smoke.jl and runtests_extract.jl pass locally.

🤖 Generated with Claude Code

The methods that take an equilibrium time slice passed the full midplane width of the last closed
surface, `r_outboard[end] - r_inboard[end]`, as the minor radius `a` of the Eich scaling
(NF 53 093031, regression #15: λq ∝ (a/Rgeo)^0.42), so λq came out 2^0.42 = 1.34 times too large.
`a` is now half of that width, as in `boundary.minor_radius`.

With the ITER parameters of the paper's table 1 (Rgeo = 6.2 m, a = 2.0 m, Bpol = 1.185 T,
Psol = 100 MW) the scaling gives 0.70 mm, against the 0.73 mm the paper quotes for this regression;
with a = 4.0 m it gives 0.94 mm.

Co-Authored-By: Claude Fable 5.2 <noreply@anthropic.com>
@tomneiser
tomneiser merged commit 18604a8 into master Nov 16, 2026
2 checks passed
@tomneiser
tomneiser deleted the fix/eich-minor-radius branch November 16, 2026 21:59
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment