This project visualizes and quantifies the correlation between estimated and true left atrial (LA) volumes. For project context, see the Background section. The workflow below focuses on running the analysis inside WSL Ubuntu using uv to manage a virtual environment and dependencies.
- Windows Subsystem for Linux (WSL) with an Ubuntu distribution.
- Python 3.10+ available inside WSL (verify with
python3 --version). pipinstalled for the WSL Python interpreter (sudo apt install python3-pipif needed).- Access to this repository from WSL. The Windows path
d:\rashe\Documents\amani-project\pythonmaps to/mnt/d/rashe/Documents/amani-project/pythoninside WSL.
python3 -m pip install --user uvIf you prefer a system-wide installation, prepend the command with sudo (optional). Ensure $HOME/.local/bin is on your PATH so that the uv executable is discoverable:
echo 'export PATH="$HOME/.local/bin:$PATH"' >> ~/.bashrc
source ~/.bashrcNavigate to the project directory (adjust the mount path if your Windows drive letter differs):
cd /mnt/d/rashe/Documents/amani-project/python
python3 -m uv venv .venvThe command above creates a .venv folder in the project root using your WSL Python interpreter.
python3 -m uv pip install --python .venv -r requirements.txtThis installs all required packages (NumPy, SciPy, Matplotlib, etc.) into .venv.
For the correlation analysis, run:
source .venv/bin/activate
python3 la_volume_correlation_analysis.pyFor the regression analysis, run:
python3 la_volume_regression_analysis.pyA Matplotlib window will open showing the scatter plot, best-fit line, and Pearson correlation coefficient. It will save the plots to a .png file
When you are finished, deactivate the environment:
deactivateuv: command not found: Make sure$HOME/.local/binis on your PATH, or rerun the install command and start a new shell session.- Display/back-end issues: If Matplotlib cannot open a window inside WSL, install an X server on Windows (e.g., VcXsrv) and export the display with
export DISPLAY=:0before running the script. Alternatively, replaceplt.show()withplt.savefig("la_volume_correlation.png")to generate an image file instead.
You are now ready to explore the LA volume correlation analysis within WSL Ubuntu.
Left atrial (LA) volume is an important clinical marker, as enlargement of the left atrium is associated with conditions such as atrial fibrillation, stroke, and heart failure. The most accurate way to measure LA volume is by performing full three-dimensional (3D) segmentation of cardiac MRI images. However, this process is time-consuming and requires specialist software and expertise.
In clinical practice, faster methods are often used that estimate LA volume from two-dimensional (2D) measurements taken from standard imaging views. These shortcut methods are quicker but rely on geometric assumptions about the shape of the atrium.
This project investigates how well a 2D-based estimation method approximates the true 3D left atrial volume. The study uses open-source cardiac MRI data and compares estimated volumes against reference volumes derived from 3D segmentation. The work was carried out as part of a student research project exploring medical image analysis techniques.
The project uses images and data from the open-source dataset LASC benchmark, Xiong et al. and the paper reference is here
Here is an infographic that describes the project:
Two different measurements of left atrial volume are compared in this project:
- The left atrial body volume is estimated using the area–length method, based on two perpendicular long-axis atrial areas and a single atrial length measurement.
- An additional volume contribution from the pulmonary veins (and the left atrial appendage) is included using a simplified cylindrical model.
- The pulmonary vein volume is estimated from 2D measurements of vein length and diameter and scaled to represent multiple venous structures.
- The reference volume is obtained from full 3D segmentation of cardiac MRI data.
- The segmentation includes the left atrial body and connected venous structures.
- This volume is treated as the ground truth for comparison.
This project compares multiple approaches for estimating left atrial (LA) volume from two-dimensional (2D) measurements and evaluates them against true three-dimensional (3D) volumes derived from MRI segmentation.
- The left atrial body volume is initially estimated using the area–length method, which approximates the atrium as an ellipsoid.
- Two perpendicular long-axis atrial areas (A1 and A2) and a single atrial length (L) are measured from 2D image views.
- The atrial body volume is calculated using the standard area–length formula.
- An additional volume contribution from the pulmonary veins (PVs) and the left atrial appendage is included using a simplified cylindrical model.
- A single pulmonary vein is measured and scaled to represent five structures (four pulmonary veins plus the appendage), matching the anatomical definition used in the 3D segmentation.
- The reference (“gold standard”) volume is obtained from full 3D segmentation of cardiac MRI data.
- The segmentation includes the left atrial body, pulmonary veins, and left atrial appendage.
- Volumes are computed directly from the segmented 3D data and used for comparison with all estimated methods.
In addition to the standard geometric area–length formula, two regression-based models are explored to investigate whether data-driven calibration can improve agreement with true 3D volumes.
Regression Model 1: Calibrated Area–Length Model
This model retains the structure of the area–length method but allows the scaling ((\alpha)) and offset ((\beta)) to be learned directly from the data using linear regression.
Regression Model 2: Multivariate Linear Model
This model treats the two atrial areas and the atrial length as independent predictors of volume and learns their relative contributions using multiple linear regression.
Both regression models are trained using measured 2D features and evaluated by comparing their predicted volumes with true 3D segmented volumes.
This repository contains Python scripts that perform correlation and regression analysis to evaluate different left atrial volume estimation methods.
la_volume_correlation_analysis.pyla_volume_regression_analysis.py
The original analysis script (la_volume_correlation_analysis.py):
- Takes paired measurements of estimated left atrial volume (2D + PV) and true 3D segmented volume
- Generates a scatter (correlation) plot comparing estimated and true volumes
- Fits a best-fit straight line using linear regression
- Computes the Pearson correlation coefficient (r)
- Visualises the strength and consistency of the relationship between estimated and true volumes
A second Python script (la_volume_regression_analysis.py) extends the analysis by fitting and visualising two regression-based volume estimation models.
This script:
- Reads atrial measurements (A1, A2, and L) and true 3D volumes from a CSV file
- Fits:
- a calibrated area–length regression model
- a multivariate linear regression model
- Computes performance metrics including correlation coefficient (R), coefficient of determination (R²), mean absolute error (MAE), and root mean square error (RMSE)
- Generates correlation plots comparing predicted versus true 3D volumes for each model
- Overlays the identity line for reference
- Displays the fitted regression equations and coefficients directly on the plots
- Saves the resulting figures as high-resolution PNG files for use in reports and presentations
Together, these scripts allow direct comparison between geometric and data-driven approaches to left atrial volume estimation.
- Python
- NumPy
- Matplotlib
- SciPy
This repository is intended for educational and research purposes only.
The script demonstrates:
- Basic validation of medical imaging measurements
- Comparison between simplified geometric models and reference 3D measurements
- Use of correlation and regression analysis in biomedical research
The code and results are not intended for clinical diagnosis or decision-making.