FCMON
Cole Smith edited this page Apr 24, 2017
·
18 revisions
FCMON (**F**orward **C**arriage **Mon**itor)
- DiagGuiServer must be running on DSC2 and FADC250 ROCs.
- For FADC250 scaler readout TET>0 mode must be enabled and pedestals loaded using
fadc250command. Config files are in$CLON_PARMS/fadc250. - For DSC2 scaler readout thresholds are set from
$CLON_PARMS/dsc2/tdc<det><sector>.cnf. These files are loaded using commanddimanv <roc> set <configfile>(e.g.-dimanv tdcecal1 set $CLON_PARMS/dsc2/tdcecal1.cnf). - For more details see
fadc250anddimanvcommands for usage information.
- Click the Radio Buttons to select the following:
- Sector (1-6)
- Detector (ECAL, PCAL, FTOF, LTCC)
- Crate (FADC, DSC2, BOTH)
- Menu item Monitor/Scalers to display scaler tabs, shown below.

- Shows scalers using slot/channel format
- Slot numbers read directly from hardware

- Shows both DSC2 discriminator and FADC250 scalers
- Used to help diagnose cable breaks and threshold settings

- Shows scaler rates in Hz using detector/view/PMT format
- Buttons for accumulating counts and Y-axis LIN/LOG

- Shows scaler rates (Z-axis) as stripcharts using detector/view/PMT format
- Buttons for Z-axis LIN/LOG and slidebar for adjusting ZMIN/ZMAX.