FoxESS and Home Assistant integration 🏡 ☀
Use hacs.io to manage the installation and update process. Right now this integration is part of HACS by default - no more neeed to add it by custom repositories 🥳
Create the folder called foxess in /homeassistant/custom_components
Copy the content of this integrations custom_components/foxess folder into your HA /homeassistant/custom_components/foxess folder
- In Home Assistant, navigate to Settings ➔ Devices & services.
- Click Add Integration and search for FoxESS.
- Step 1 - API Key: Enter your personal
apiKey(masked password field with toggle 👁️). - Step 2 - Select Inverter: Select your inverter from the discovered devices list (pre-selected automatically if you have one inverter).
- If you have multiple inverters in your FoxESS account, simply click Add Integration again to add each additional inverter.
- Log into the FoxESS OpenAPI Developer Portal at developer-eu.foxesscloud.com/apiKeys (or developer-us.foxesscloud.com for US accounts) using your FoxESS Cloud account credentials.
- Click Generate API Key (or copy your existing key).
- Paste the API key into the Home Assistant setup form.
You can adjust settings for each configured inverter at any time without restarting Home Assistant:
- Go to Settings ➔ Devices & services ➔ FoxESS.
- Click Configure on the inverter entry card:
- Assigned Inverter: Displays the serial number (
deviceSN) for this device (read-only). - API Key: Update or change your FoxESS API key.
- Daily energy sanity check threshold (kWh) (
energyGeneratedSanityCheck): Maximum expected daily energy generation in kWh (default:100.0kWh). Readings above this threshold are ignored to protect Energy Dashboard statistics from corrupted spikes (e.g. when FoxESS Cloud erroneously reports lifetime yield instead of daily yield). - Reduced API calls mode (Eco mode) (
reduceAPICalls): Halves API polling frequency (10-minute intervals for real-time telemetry, 30-minute intervals for status details, 60-minute intervals for reports) to prevent hitting the FoxESS 1,440 daily call quota. Recommended for multi-inverter setups or systems connected to external Virtual Power Plant (VPP) providers (e.g. Amber Electric, Evergen). - Show zero when inverter is offline (
show_unknown_zero): When enabled, power, current, and voltage sensors cleanly report0.0instead of falling intounavailable/unknownwhen the inverter or micro-inverter is offline after sunset, and cumulative energy totals are retained. - Extended PV strings (
extendPV): Enable for Fox R series or inverters supporting more than 6 PV strings (reads PV strings 7–18). - FoxESS EVO series mode (
Evo): Enable if using a FoxESS EVO series inverter where device details are incomplete. - Cross Time Zone adjustment (
xtZone): Enable if inverter timestamps use a different time zone than Home Assistant. - Restrict API variables (
Restrict): Restrict variable queries to essential telemetry if Fox Cloud returns errors for large variable lists.
- Assigned Inverter: Displays the serial number (
| Parameter | Type | Default | Description |
|---|---|---|---|
apiKey |
string | Required | FoxESS OpenAPI token generated in the FoxESS Developer Portal. |
deviceSN |
string | Required | Inverter serial number from Foxess Cloud. |
deviceID |
string | deviceSN |
Inverter ID. Reuses deviceSN for all modern setups. Preserves legacy UUID on older setups. |
name |
string | "FoxESS" |
Friendly name prefix for inverter entities and device title. |
energyGeneratedSanityCheck |
float | 100.0 |
Daily generation ceiling (kWh). Spikes exceeding this value are rejected to safeguard Energy Dashboard statistics. |
reduceAPICalls |
boolean | false |
Enable reduced API call frequency (10-minute polling) to conserve daily quota on accounts with multiple inverters or external VPP providers. |
show_unknown_zero |
boolean | false |
When enabled, reports 0 for power, current, and voltage instead of unavailable when the inverter is offline (e.g. micro-inverters at night) and retains cumulative energy totals. |
extendPV |
boolean | false |
Enable to read additional PV strings 7–18 for inverters with >6 strings. |
Evo |
boolean | false |
Enable support for FoxESS EVO series inverters. |
xtZone |
boolean | false |
Adjust time zone offset if inverter timestamps differ from HA local time. |
Restrict |
boolean | false |
Limit API variable queries to prevent timeout/payload issues on certain inverters. |
Use_V1_Api |
boolean | true |
Use modern OpenAPI v1 endpoints (/op/v1/device/...) for real-time telemetry. Set to false to fall back to legacy v0 endpoints (/op/v0/device/...) if required by older accounts. |
If you previously configured FoxESS using configuration.yaml:
- When Home Assistant starts with this version, your configuration will be automatically imported into a UI Config Entry.
- Zero data loss: All entity unique IDs (
{deviceID}{suffix}) and historical sensor statistics are preserved. - A persistent notification will appear in Home Assistant confirming successful migration.
- After migration, you can safely remove the
foxessblock from yourconfiguration.yaml.
⌨️ Legacy YAML Configuration (Deprecated)
[!NOTE] YAML configuration is deprecated and will be removed in a future release. Please use the UI configuration flow instead.
sensor:
- platform: foxess
deviceID: enter_your_inverter_serial_number
deviceSN: enter_your_inverter_serial_number
apiKey: enter_your_personal_api_keyyour_personal_api_key: generated at developer-eu.foxesscloud.com/apiKeys (or developer-us.foxesscloud.com for US accounts).deviceSN: inverter serial number from Foxesscloud.com under Device -> Inverter.deviceID: for all installations since March 2024, reusedeviceSNasdeviceID. For older legacy installations, keep the original inverter UUID from the Foxess Cloud URL to preserve historical entity unique IDs.extendPV: set totrueif your inverter has more than 6 PV strings.
Multi-inverter YAML example:
sensor:
- platform: foxess
name: Fox1
deviceID: enter_your_inverter_id_1
deviceSN: enter_your_inverter_serial_number_1
apiKey: enter_your_personal_api_key_1
- platform: foxess
name: Fox2
deviceID: enter_your_inverter_id_2
deviceSN: enter_your_inverter_serial_number_2
apiKey: enter_your_personal_api_key_2For systems equipped with a battery, this integration exposes direct controls and automation services via FoxESS Cloud OpenAPI:
| Entity | Platform | Domain | Description |
|---|---|---|---|
| FoxESS - Work Mode | select |
select |
Switch inverter operating mode: Self-Use, Feed-in, Backup, or Peak Shaving. Automatically rejects manual changes when Mode Scheduler is active to prevent cloud conflict error 44096. |
| FoxESS - Min SoC | number |
number |
Minimum battery State of Charge off-grid (10–100%, step 1). Clamped automatically so Min SoC <= Min SoC on Grid. |
| FoxESS - Min SoC on Grid | number |
number |
Minimum battery State of Charge while connected to grid (10–100%, step 1). Clamped automatically so Min SoC on Grid >= Min SoC. |
| FoxESS - Mode Scheduler | switch |
switch |
Toggle cloud scheduler on/off. Configured scheduler groups and force charge times are exposed in entity attributes. |
Note
For PV-only installations without a battery (hasBattery: false), battery controls and scheduler platforms are automatically skipped.
FoxESS Cloud OpenAPI offers two distinct approaches for battery charging and scheduling depending on the inverter model:
- New API (Mode Scheduler): Supported by modern inverters (H1 G2, H3, KH, H3-Pro, etc.). Uses
/op/v1/device/scheduler/...and/op/v2/device/scheduler/...to define dynamic multi-segment schedules with selectable work modes (ForceCharge,ForceDischarge,SelfUse). - Legacy API (Force Charge Times): Supported by older generation inverters and All-in-One series (e.g. AIO-H3, AC1) where the FoxESS Cloud does not support the Mode Scheduler module (returning an unsupported scheduler error). Uses
/op/v0/device/battery/forceChargeTime/getand/setto configure two grid force-charge time periods.
Overwrites the FoxESS Mode Scheduler with configured time slots and operating modes (ideal for dynamic tariff charging, e.g. Octopus Agile, Nord Pool, Tibber):
Important
FoxESS Cloud Scheduler Specifications & Boundaries:
- 8-Slot Limit: The FoxESS Cloud OpenAPI enforces a strict maximum of 8 schedule groups (positional slots). Writing more than 8 groups will raise an error.
- Parameter Semantics (
extraParam):ForceCharge:extraParam.maxSocspecifies the charge-to target (Period Max SOC).SelfUse:extraParam.minSocOnGridspecifies the minimum discharge floor (Period Min SOC).Backup: Prevents household battery discharge;extraParam.minSocOnGridspecifies the floor.
- Remaining Time Mode: Writing a schedule resets the FoxESS app's Remaining Time Mode to
Self-use. If you want idle periods outside active charging windows to hold charge rather than discharge, define explicitBackupgroups.
action: foxess.set_schedule
data:
device_sn: "60BH1234567"
enable: true
groups:
# 1. Cheap slot: Force Charge from grid up to 85% SoC
- enable: 1
startHour: 2
startMinute: 0
endHour: 5
endMinute: 0
workMode: "ForceCharge"
extraParam:
maxSoc: 85
minSocOnGrid: 20
fdPwr: 0
fdSoc: 100
# 2. Peak slot: Discharge for self-use down to 30% floor
- enable: 1
startHour: 17
startMinute: 0
endHour: 21
endMinute: 0
workMode: "SelfUse"
extraParam:
minSocOnGrid: 30
maxSoc: 100
fdPwr: 0
fdSoc: 100
# 3. Night hold: Prevent discharge using Backup mode
- enable: 1
startHour: 21
startMinute: 0
endHour: 23
endMinute: 59
workMode: "Backup"
extraParam:
minSocOnGrid: 30
maxSoc: 100
fdPwr: 0
fdSoc: 100Configures grid force-charging time windows for inverters supporting the legacy forceChargeTime API (such as AIO-H3, AC1, and models without Mode Scheduler support):
action: foxess.set_force_charge_times
data:
device_sn: "60BH1234567"
enable_1: true
start_time_1: "02:00"
end_time_1: "05:00"
enable_2: false
start_time_2: "14:00"
end_time_2: "16:00"| HA Entity | Measurement |
|---|---|
| Inverter | string on-line/off-line/in-alarm - attributes Master, Manager, Slave versions & Battery details where fitted |
| Generation Power | kW |
| Grid Consumption Power | kW |
| FeedIn Power | kW |
| Bat Discharge Power | kW |
| Bat Charge Power | kW |
| Solar Power | kW |
| Load Power | kW |
| Meter2 Power | kW |
| PV1 Current | A |
| PV1 Power | kW |
| PV1 Volt | V |
| PV2 Current | A |
| PV2 Power | kW |
| PV2 Volt | V |
| PV3 Current | A |
| PV3 Power | kW |
| PV3 Volt | V |
| PV4 Current | A |
| PV4 Power | kW |
| PV4 Volt | V |
| PV Power | kW |
| R Current | A |
| R Freq | Hz |
| R Power | kW |
| R Volt | V |
| S Current | A |
| S Freq | Hz |
| S Power | kW |
| S Volt | V |
| T Current | A |
| T Freq | Hz |
| T Power | kW |
| T Volt | V |
| Reactive Power | kVar |
| PV Production Total | kWh |
| Energy Generated | kWh |
| Energy Generated Month | kWh |
| Energy Throughput | kWh |
| Grid Consumption | kWh |
| FeedIn | kWh |
| Solar | kWh |
| Load | kWh |
| Bat Charge | kWh |
| Bat Discharge | kWh |
| Bat SoC | % (single battery systems) |
| Bat SoC1 | % (dual battery systems) |
| Bat SoC2 | % (dual battery systems) |
| Bat SoH | % (single battery systems where BMS supports it) |
| Max Bat Charge Current | A |
| Max Bat Discharge Current | A |
| Inverter Bat Power | kW (negative=charging, positive=discharging) |
| Inverter Bat Power2 | kW (dual battery systems |
| Bat Temperature | °C |
| Bat Temperature2 | °C (dual battery systems) |
| Ambient Temp | °C |
| Boost Temp | °C |
| Inv Temp | °C |
| Residual Energy | kWh |
| minSoC | % |
| minSoC on Grid | % |
| Power Factor | % |
| API Response Time | mS |
| Running State | string 163: on-grid (see Table1) |
Table1 Possible Running States
| Running State |
|---|
| 160: self-test |
| 161: waiting |
| 162: checking |
| 163: on-grid |
| 164: off-grid |
| 165: fault |
| 166: permanent-fault |
| 167: standby |
| 168: upgrading |
| 169: fct |
| 170: illegal |
💡 If you want to understand energy generation per string check out this wiki article
API Error summary:
{"errno":41930,"result":null}⟶ incorrect inverter id{"errno":40261,"result":null}⟶ incorrect inverter id{"errno":41807,"result":null}⟶ wrong user name or password{"errno":41808,"result":null}⟶ token expired{"errno":41809,"result":null}⟶ invalid token{"errno":40256,"result":null}⟶ Request header parameters are missing. Check whether the request headers are consistent with OpenAPI requirements.{"errno":40257,"result":null}⟶ Request body parameters are invalid. Check whether the request body is consistent with OpenAPI requirements.{"errno":40400,"result":null}⟶ The number of requests is too frequent. Please reduce the frequency of access.
Increase log level in your /configuration.yaml by adding:
logger:
default: warning
logs:
custom_components.foxess: debugFoxESS provide an OpenAPI that allows registered users to make request to return datasets.
The OpenAPI access is limited and each user must have an apiKey to access it. This API key can be generated by logging into the FoxESS Developer Portal at developer-eu.foxesscloud.com/apiKeys (or developer-us.foxesscloud.com for US accounts) using your FoxESS Cloud account credentials and clicking 'Generate API Key'. Copy this key and use it to configure the integration.
The OpenAPI has a limit of 1,440 API calls per day, after which the OpenAPI will stop responding to requests and generate a "40400" error.
This sounds like a large number of calls, but bear in mind that multiple API calls have to be made on each scan to gain the complete dataset for a system.
The integration paces the number of API calls that are made, with the following frequency -
- Site status and plant details - every 15 minutes
- Real time variables - every 5 minutes
- Cumulative total reports (generation, feedin, gridConsumption, BatterychargeTotal, Batterydischargetotal, home load) - every 15 minutes
- Daily Generation report (Daily Energy Generated - 'total yield') - every 60 minutes
- Battery minSoC settings - every 60 minutes
The integration is using approximately 22 API calls an hour (528 a day and well within the 1,440).
If you have multiple inverters in your account, you will receive 1,440 calls per inverter, so for 2 inverters you will have 2,880 api calls.
If your FoxESS account is shared with an external Virtual Power Plant (VPP) provider (e.g. Amber Electric, Evergen, Reposit) or you have multiple inverters and are approaching the 1,440 calls/day limit, enable Reduced API calls mode (Eco mode) in the integration settings (Settings ➔ Devices & services ➔ FoxESS ➔ Configure):
- Real time telemetry: every 10 minutes (instead of 5 minutes)
- Site status and device details: every 30 minutes (instead of 15 minutes)
- Energy total reports: every 60 minutes (instead of 15 minutes)
- Daily generation report: every 60 minutes
- Battery minSoC settings: every 60 minutes
This reduces polling to approximately 11 API calls per hour (~264 calls per day per inverter), cutting API consumption by more than 50% and ensuring your setup remains safely below daily quota limits.