1 change: 1 addition & 0 deletions packages/control/bat.py
Original file line number Diff line number Diff line change
Expand Up @@ -42,6 +42,7 @@ def get_factory() -> Get:
@dataclass
class Set:
power_limit: Optional[int] = field(default=None, metadata={"topic": "set/power_limit"})
evu_power: Optional[int] = field(default=None, metadata={"topic": "set/evu_power"})


def set_factory() -> Set:
Expand Down
3 changes: 2 additions & 1 deletion packages/control/bat_all.py
Original file line number Diff line number Diff line change
Expand Up @@ -297,7 +297,8 @@ def _set_bat_power_active_control(self, power):
log.debug(("Aktive Speichersteuerung: Ladung - "
f"Speicher (ID: {bat_component.component_config.id}) "
f"laden mit {power_limit} ({factor} x {bat_component_data.get.max_charge_power}) W"))
data.data.bat_data[f"bat{bat_component.component_config.id}"].data.set.power_limit = power_limit
bat_component_data.set.power_limit = power_limit
bat_component_data.set.evu_power = data.data.counter_all_data.get_evu_counter().data.get.power

def setup_bat(self):
""" prüft, ob mind ein Speicher vorhanden ist und berechnet die Summen-Topics.
Expand Down
2 changes: 1 addition & 1 deletion packages/control/process.py
Original file line number Diff line number Diff line change
Expand Up @@ -69,7 +69,7 @@ def process_algorithm_results(self) -> None:
Thread(
target=set_power_limit_wrapper,
args=(bat_component,
data.data.bat_data[f"bat{bat_component.component_config.id}"].data.set.power_limit),
data.data.bat_data[f"bat{bat_component.component_config.id}"].data.set),
name=f"set power limit {bat_component.component_config.id}"))
for action in data.data.io_actions.actions.values():
if isinstance(action, DimmingDirectControl):
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -20,6 +20,7 @@ def _get_data_path() -> Path:
INTERNAL_TOPICS = ['openWB/bat/set/charging_power_left',
'openWB/bat/set/regulate_up',
'openWB/bat/+/set/power_limit',
'openWB/bat/+/set/evu_power',
'openWB/command/max_id/autolock_plan',
'openWB/command/max_id/charge_template',
'openWB/command/max_id/charge_template_scheduled_plan',
Expand Down
2 changes: 2 additions & 0 deletions packages/helpermodules/setdata.py
Original file line number Diff line number Diff line change
Expand Up @@ -734,6 +734,8 @@ def process_bat_topic(self, msg: mqtt.MQTTMessage):
self._validate_value(msg, bool)
elif "/set/power_limit" in msg.topic:
self._validate_value(msg, float)
elif "/set/evu_power" in msg.topic:
self._validate_value(msg, float)
else:
self.__unknown_topic(msg)
else:
Expand Down
1 change: 1 addition & 0 deletions packages/helpermodules/update_config.py
Original file line number Diff line number Diff line change
Expand Up @@ -98,6 +98,7 @@ class UpdateConfig:
"^openWB/bat/[0-9]+/get/fault_str$",
"^openWB/bat/[0-9]+/get/power_limit_controllable$",
"^openWB/bat/[0-9]+/set/power_limit$",
"^openWB/bat/[0-9]+/set/evu_power$",

"^openWB/chargepoint/get/power$",
"^openWB/chargepoint/get/exported$",
Expand Down
5 changes: 3 additions & 2 deletions packages/modules/common/configurable_device.py
Original file line number Diff line number Diff line change
Expand Up @@ -8,6 +8,7 @@
from modules.common.abstract_device import AbstractBat, AbstractDevice
from modules.common.component_context import SingleComponentUpdateContext, MultiComponentUpdateContext
from modules.common.fault_state import ComponentInfo, FaultState
from control.bat import Set as SetPoint

T_DEVICE_CONFIG = TypeVar("T_DEVICE_CONFIG")
T_COMPONENT = TypeVar("T_COMPONENT")
Expand Down Expand Up @@ -130,9 +131,9 @@ def update(self):
self.__component_updater(initialized_components, self.error_handler)


def set_power_limit_wrapper(bat_component: AbstractBat, power_limit: Optional[int]):
def set_power_limit_wrapper(bat_component: AbstractBat, setpoint: Optional[SetPoint]):
"""set_power_limit innerhalb des SingleComponentUpdateContext aufrufen,
damit Fehler im fault_state-Handler behandelt werden
"""
with SingleComponentUpdateContext(bat_component.fault_state, update_always=False):
bat_component.set_power_limit(power_limit)
bat_component.set_power_limit(setpoint)
9 changes: 5 additions & 4 deletions packages/modules/devices/alpha_ess/alpha_ess/bat.py
Original file line number Diff line number Diff line change
@@ -1,6 +1,6 @@
import logging
import time
from typing import TypedDict, Any, Optional
from typing import TypedDict, Any
from modules.common.abstract_device import AbstractBat
from modules.common.component_state import BatState
from modules.common.component_type import ComponentDescriptor
Expand All @@ -11,6 +11,7 @@
from modules.devices.alpha_ess.alpha_ess.config import AlphaEssBatSetup
from modules.common.utils.peak_filter import PeakFilter
from modules.common.component_type import ComponentType
from control.bat import Set as SetPoint

log = logging.getLogger(__name__)

Expand Down Expand Up @@ -62,16 +63,16 @@ def update(self) -> None:
)
self.store.set(bat_state)

def set_power_limit(self, power_limit: Optional[int]) -> None:
def set_power_limit(self, setpoint: SetPoint) -> None:
unit = self.__modbus_id

if power_limit is None:
if setpoint.power_limit is None:
# Kein Powerlimit gefordert, externe Steuerung deaktivieren
log.debug("Keine Batteriesteuerung gefordert, deaktiviere externe Steuerung.")
if self.last_mode is not None:
self.__tcp_client.write_register(2127, 0, data_type=ModbusDataType.UINT_16, unit=unit)
self.last_mode = None
elif power_limit <= 0:
elif setpoint.power_limit <= 0:
# AlphaESS kann die Entladung nur über den SoC verhindern (komplette Entladesperre)
# Netzladung mit geringen Ziel SoC verhindert auch Entladung (Default 10%)
# Zeiten für Netzladung müssen im Wechselrichter aktiviert werden
Expand Down
11 changes: 6 additions & 5 deletions packages/modules/devices/anker/solarbank/bat.py
Original file line number Diff line number Diff line change
@@ -1,6 +1,6 @@
#!/usr/bin/env python3
import logging
from typing import Any, Optional, TypedDict
from typing import Any, TypedDict

from modules.common.abstract_device import AbstractBat
from modules.common.component_state import BatState
Expand All @@ -12,6 +12,7 @@
from modules.devices.anker.solarbank.config import Anker, AnkerBatSetup
from modules.common.utils.peak_filter import PeakFilter
from modules.common.component_type import ComponentType
from control.bat import Set as SetPoint

log = logging.getLogger(__name__)

Expand Down Expand Up @@ -52,10 +53,10 @@ def update(self) -> None:
)
self.store.set(bat_state)

def set_power_limit(self, power_limit: Optional[int]) -> None:
def set_power_limit(self, setpoint: SetPoint) -> None:
unit = self.device_config.configuration.modbus_id

if power_limit is None:
if setpoint.power_limit is None:
log.debug("Keine Batteriesteuerung, Selbstregelung durch Wechselrichter")
if self.last_mode is not None:
self.client.write_register(10064, 0, data_type=ModbusDataType.UINT_16, unit=unit)
Expand All @@ -65,9 +66,9 @@ def set_power_limit(self, power_limit: Optional[int]) -> None:
self.client.write_register(10064, 3, data_type=ModbusDataType.UINT_16, unit=unit)
self.last_mode = 'limited'

power_value = 0 if power_limit == 0 else int(power_limit) * -1
power_value = 0 if setpoint.power_limit == 0 else int(setpoint.power_limit) * -1
self.client.write_register(10071, power_value, data_type=ModbusDataType.INT_32, unit=unit)
log.debug("Aktive Batteriesteuerung angefordert, angeforderte Leistung: {power_value} W")
log.debug(f"Aktive Batteriesteuerung angefordert, angeforderte Leistung: {power_value} W")

def power_limit_controllable(self) -> bool:
return True
Expand Down
9 changes: 5 additions & 4 deletions packages/modules/devices/batterx/batterx/bat.py
Original file line number Diff line number Diff line change
@@ -1,6 +1,6 @@
#!/usr/bin/env python3
import logging
from typing import Dict, TypedDict, Any, Optional
from typing import Dict, TypedDict, Any

from modules.devices.batterx.batterx.config import BatterXBatSetup
from modules.common.abstract_device import AbstractBat
Expand All @@ -12,6 +12,7 @@
from modules.common import req
from modules.common.utils.peak_filter import PeakFilter
from modules.common.component_type import ComponentType
from control.bat import Set as SetPoint

log = logging.getLogger(__name__)

Expand Down Expand Up @@ -49,10 +50,10 @@ def update(self, resp: Dict) -> None:
)
self.store.set(bat_state)

def set_power_limit(self, power_limit: Optional[int]) -> None:
def set_power_limit(self, setpoint: SetPoint) -> None:
log.debug(f'last_mode: {self.last_mode}')

if power_limit is None:
if setpoint.power_limit is None:
# Kein Powerlimit gefordert, externe Steuerung deaktivieren
log.debug("Keine Batteriesteuerung gefordert, deaktiviere externe Steuerung.")
if self.last_mode is not None:
Expand All @@ -67,7 +68,7 @@ def set_power_limit(self, power_limit: Optional[int]) -> None:
timeout=5
)
self.last_mode = None
elif power_limit <= 0:
elif setpoint.power_limit <= 0:
# BatterX kann Entladung nur komplett sperren
log.debug("Aktive Batteriesteuerung angestoßen. Setze Entladesperre.")
if self.last_mode != 'stop':
Expand Down
7 changes: 4 additions & 3 deletions packages/modules/devices/generic/mqtt/bat.py
Original file line number Diff line number Diff line change
@@ -1,5 +1,5 @@
#!/usr/bin/env python3
from typing import Any, Dict, Optional, TypedDict
from typing import Any, Dict, TypedDict

from helpermodules.pub import Pub
from helpermodules.utils._get_default import get_default
Expand All @@ -12,6 +12,7 @@
from modules.devices.generic.mqtt.config import MqttBatSetup
from modules.common.utils.peak_filter import PeakFilter
from modules.common.component_type import ComponentType
from control.bat import Set as SetPoint


class KwargsDict(TypedDict):
Expand Down Expand Up @@ -55,8 +56,8 @@ def parse_received_topics(value: str):
)
self.store.set(bat_state)

def set_power_limit(self, power_limit: Optional[int]) -> None:
Pub().pub(f"openWB/set/mqtt/bat/{self.component_config.id}/set/power_limit", power_limit)
def set_power_limit(self, setpoint: SetPoint) -> None:
Pub().pub(f"openWB/set/mqtt/bat/{self.component_config.id}/set/power_limit", setpoint.power_limit)

def power_limit_controllable(self) -> bool:
return self.component_config.configuration.power_limit_controllable
Expand Down
22 changes: 12 additions & 10 deletions packages/modules/devices/good_we/good_we/bat.py
Original file line number Diff line number Diff line change
@@ -1,5 +1,5 @@
#!/usr/bin/env python3
from typing import TypedDict, Any, Optional
from typing import TypedDict, Any
import logging

from modules.common import modbus
Expand All @@ -14,6 +14,7 @@
from modules.devices.good_we.good_we.version import GoodWeVersion
from modules.common.utils.peak_filter import PeakFilter
from modules.common.component_type import ComponentType
from control.bat import Set as SetPoint

log = logging.getLogger(__name__)

Expand Down Expand Up @@ -73,37 +74,38 @@ def update(self) -> None:
)
self.store.set(bat_state)

def set_power_limit(self, power_limit: Optional[int]) -> None:
def set_power_limit(self, setpoint: SetPoint) -> None:
unit = self.__modbus_id
log.debug(f'last_mode: {self.last_mode}')

if power_limit is None:
if setpoint.power_limit is None:
log.debug("Keine Batteriesteuerung, Selbstregelung durch Wechselrichter")
if self.last_mode is not None:
self.__tcp_client.write_register(47511, 1, data_type=ModbusDataType.UINT_16, unit=unit)
self.__tcp_client.write_register(47512, 0, data_type=ModbusDataType.UINT_16, unit=unit)
self.last_mode = None
elif power_limit == 0:
elif setpoint.power_limit == 0:
log.debug("Aktive Batteriesteuerung. Batterie wird auf Stop gesetzt und nicht entladen")
if self.last_mode != 'stop':
self.__tcp_client.write_register(47511, 2, data_type=ModbusDataType.UINT_16, unit=unit)
self.__tcp_client.write_register(47512, 0, data_type=ModbusDataType.UINT_16, unit=unit)
self.last_mode = 'stop'
elif power_limit < 0:
log.debug(f"Aktive Batteriesteuerung. Batterie wird mit {power_limit} W entladen für den Hausverbrauch")
elif setpoint.power_limit < 0:
log.debug(f"Aktive Batteriesteuerung. Batterie wird mit {setpoint.power_limit} W "
"entladen für den Hausverbrauch")
if self.last_mode != 'discharge':
self.__tcp_client.write_register(47511, 3, data_type=ModbusDataType.UINT_16, unit=unit)
self.last_mode = 'discharge'
# Die maximale Entladeleistung begrenzen auf 5000W, maximaler Wertebereich Modbusregister.
power_value = int(min(abs(power_limit), 10000))
power_value = int(min(abs(setpoint.power_limit), 10000))
log.debug(f"Aktive Batteriesteuerung. Batterie wird mit {power_value} W entladen für den Hausverbrauch")
self.__tcp_client.write_register(47512, power_value, data_type=ModbusDataType.UINT_16, unit=unit)
elif power_limit > 0:
elif setpoint.power_limit > 0:
if self.last_mode != 'charge':
self.__tcp_client.write_register(47511, 2, data_type=ModbusDataType.UINT_16, unit=unit)
self.last_mode = 'charge'
power_value = int(min(abs(power_limit), 10000))
log.debug(f"Aktive Batteriesteuerung. Batterie wird mit {power_value} W entladen für den Hausverbrauch")
power_value = int(min(abs(setpoint.power_limit), 10000))
log.debug(f"Aktive Batteriesteuerung. Batterie wird mit {power_value} W geladen.")
self.__tcp_client.write_register(47512, power_value, data_type=ModbusDataType.UINT_16, unit=unit)

def power_limit_controllable(self) -> bool:
Expand Down
17 changes: 9 additions & 8 deletions packages/modules/devices/kostal/kostal_plenticore/bat.py
Original file line number Diff line number Diff line change
@@ -1,6 +1,6 @@
#!/usr/bin/env python3
import logging
from typing import TypedDict, Any, Optional
from typing import TypedDict, Any
from pymodbus.constants import Endian

from modules.common.abstract_device import AbstractBat
Expand All @@ -13,6 +13,7 @@
from modules.devices.kostal.kostal_plenticore.config import KostalPlenticoreBatSetup
from modules.common.utils.peak_filter import PeakFilter
from modules.common.component_type import ComponentType
from control.bat import Set as SetPoint

log = logging.getLogger(__name__)

Expand Down Expand Up @@ -67,24 +68,24 @@ def update(self) -> None:
# Kostal setzt das Register autmatisch nach Timeout zurück auf Eigensteuerung.
# Timeout kann im Kostal UI geändert werden. Standardwert 30s

def set_power_limit(self, power_limit: Optional[int]) -> None:
def set_power_limit(self, setpoint: SetPoint) -> None:
unit = self.modbus_id

if power_limit is None:
if setpoint.power_limit is None:
# Keine Registeränderung damit nach Timeout eigenständig zurückgesetzt wird
log.debug("Keine Batteriesteuerung, Selbstregelung durch Wechselrichter")
elif power_limit == 0:
elif setpoint.power_limit == 0:
# wiederholt auf Stop setzen damit sich Register nicht zurücksetzt
log.debug("Aktive Batteriesteuerung. Batterie wird auf Stop gesetzt und nicht entladen")
self.client.write_register(1034, 0.0, data_type=ModbusDataType.FLOAT_32,
wordorder=self.endianess, unit=unit)
elif power_limit < 0:
power_value = float(abs(power_limit))
elif setpoint.power_limit < 0:
power_value = float(abs(setpoint.power_limit))
log.debug(f"Aktive Batteriesteuerung. Batterie wird mit {power_value} W entladen für den Hausverbrauch")
self.client.write_register(1034, power_value, data_type=ModbusDataType.FLOAT_32,
wordorder=self.endianess, unit=unit)
elif power_limit > 0:
power_value = float(abs(power_limit)) * -1
elif setpoint.power_limit > 0:
power_value = float(abs(setpoint.power_limit)) * -1
log.debug(f"Aktive Batteriesteuerung. Batterie wird mit {power_value} W geladen")
self.client.write_register(1034, power_value, data_type=ModbusDataType.FLOAT_32,
wordorder=self.endianess, unit=unit)
Expand Down
15 changes: 8 additions & 7 deletions packages/modules/devices/marstek/venus_c_e/bat.py
Original file line number Diff line number Diff line change
@@ -1,5 +1,5 @@
#!/usr/bin/env python3
from typing import Optional, TypedDict, Any, Union
from typing import TypedDict, Any, Union
from modules.common.abstract_device import AbstractBat
from modules.common.component_state import BatState
from modules.common.component_type import ComponentDescriptor
Expand All @@ -10,6 +10,7 @@
from modules.devices.marstek.venus_c_e.config import VenusCEBatSetup
from modules.common.utils.peak_filter import PeakFilter
from modules.common.component_type import ComponentType
from control.bat import Set as SetPoint


class KwargsDict(TypedDict):
Expand Down Expand Up @@ -53,20 +54,20 @@ def update(self) -> None:
)
self.store.set(bat_state)

def set_power_limit(self, power_limit: Optional[int]) -> None:
def set_power_limit(self, setpoint: SetPoint) -> None:
# Wenn der Speicher die Steuerung der Ladeleistung unterstützt, muss bei Übergabe einer Zahl auf aktive
# Speichersteurung umgeschaltet werden, sodass der Speicher mit der übergebenen Leistung lädt/entlädt. Wird
# None übergeben, muss der Speicher die Null-Punkt-Ausregelung selbst übernehmen.
if (power_limit is None):
if (setpoint.power_limit is None):
self._write_reg(42000, 0x55bb)
else:
self._write_reg(42000, 0x55aa)
if power_limit < 0:
if setpoint.power_limit < 0:
self._write_reg(42010, 2)
self._write_reg(42021, int(min(-power_limit, 2500)))
elif power_limit > 0:
self._write_reg(42021, int(min(-setpoint.power_limit, 2500)))
elif setpoint.power_limit > 0:
self._write_reg(42010, 1)
self._write_reg(42020, int(min(power_limit, 2500)))
self._write_reg(42020, int(min(setpoint.power_limit, 2500)))
else:
self._write_reg(42010, 0)

Expand Down
Loading