Repository navigation
Description
Before opening
- I searched the existing issues and this is not a duplicate.
- I am on the latest addhOn release (stable or beta).
addhOn version
5.29.0
Home Assistant version
2026.11.0
Appliance type
Air conditioner (AC)
Appliance model
AS35SBBHRA-MB (also seen on AS25SBBHRA-MB and AS50SDBHRA-MB, Haier Flexis)
What happens, and what did you expect?
The AC total_energy sensor (sensor.<ac>_air_conditioner_total_energy, attribute totalElectricityUsed) is declared with native_unit_of_measurement=UnitOfEnergy.KILO_WATT_HOUR, but these units report the counter in Wh. The entity therefore shows values 1000× too high.
Compared with the hOn app: for the AS25SBBHRA-MB unit the raw totalElectricityUsed is 26, Home Assistant shows 26 kWh, and the hOn app shows 0.02 kWh.
Readings of the AS35SBBHRA-MB while heating (raw totalElectricityUsed, local time, 2026-11-09):
| Time | Raw value | Δ | Interval | Average power if Wh | if kWh |
|---|---|---|---|---|---|
| 19:31 | 45954 | +176 | 16 min | 660 W | 660 kW |
| 19:47 | 46031 | +77 | 16 min | 289 W | 289 kW |
| 20:03 | 46189 | +158 | 16 min | 593 W | 593 kW |
| 21:07 | 46696 | +146 | 16 min | 548 W | 548 kW |
| 21:23 | 46778 | +82 | 16 min | 308 W | 308 kW |
| 21:39 | 46927 | +149 | 16 min | 559 W | 559 kW |
| 21:55 | 47037 | +110 | 16 min | 413 W | 413 kW |
300–700 W is what a 3.5 kW heat pump draws at part load; 300–700 kW is impossible. Over the 12 days since the unit was added the counter went from 289 to 47037: about 47 kWh (≈3.9 kWh/day) if Wh, versus 47 MWh if kWh.
accumulatedUseMainsPower carries the same value as totalElectricityUsed on all three units (26 / 338 / 47037).
Expected: the sensor shows kWh (raw value / 1000).
Note: the comment above _AC in sensor.py says AS-class ACs report 0 for totalElectricityUsed. These units (2026 Flexis, S*BHRA-MB) report a live counter in Wh, so the sensor is useful once the unit is fixed.
Suggested fix: declare the native unit as Wh and let Home Assistant display kWh:
HonSensorEntityDescription(
key="total_energy",
translation_key="ac_total_energy",
attr_key=AC_ATTR_TOTAL_ENERGY,
native_unit_of_measurement=UnitOfEnergy.WATT_HOUR,
suggested_unit_of_measurement=UnitOfEnergy.KILO_WATT_HOUR,
device_class=SensorDeviceClass.ENERGY,
state_class=SensorStateClass.TOTAL_INCREASING,
),
Users who already have this sensor have long-term statistics recorded ×1000. After the fix the value drops by 1000, which the recorder treats as a meter reset, so a note in the release changelog would help.
Local workaround I'm running meanwhile: a value_fn that divides by 1000, keeping the native unit as kWh:
def _wh_to_kwh(raw) -> float | None:
if raw is None:
return None
try:
return round(float(raw) / 1000, 3)
except (ValueError, TypeError):
return None
and value_fn=_wh_to_kwh on the AC total_energy description.
Steps to reproduce
- Add a Haier Flexis AC (e.g. AS35SBBHRA-MB) through addhOn.
- Run it in heat or cool mode for an hour or more.
- Compare
sensor.<ac>_air_conditioner_total_energywith the energy shown in the hOn app, or with the change in the rawtotalElectricityUsedover time.
Error code
No response
Diagnostics file
Debug log
No response
Activity
github-actions commentedon Nov 9, 2026
Thanks @SusoINC, we received your issue.
We'll reply as soon as we can; no reply yet means we're already working on it.
If we need more details or tests, we'll ask here.
fix(sensor): the air conditioner energy counter is read in Wh, not kWh (
feat(sensor): the air conditioner reports the power it draws, from ac…
fix(sensor): a power reading that is not finite is unknown, and revie…
tis24dev commentedon Nov 11, 2026
@SusoINC Hi, install the latest release and let me know what you think... I hope that solves the problem.
SusoINC commentedon Nov 12, 2026
@tis24dev
Thanks for the fix! Now it looks fine :)
github-actions commentedon Nov 12, 2026
@SusoINC thanks for using addhOn!