Repository navigation
Fix filter_lambda minimum and infinite loop with small/zero current step #261
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Open
maroba
wants to merge
1
commit into
ECSIM:develop
Choose a base branch
from
maroba:fix/lambda-and-precision
base: develop
Could not load branches
Branch not found: {{ refName }}
Loading
Could not load tags
Nothing to show
Loading
Are you sure you want to change the base?
Some commits from the old base branch may be removed from the timeline,
and old review comments may become outdated.
Open
Changes from all commits
Commits
File filter
Filter by extension
Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
There are no files selected for viewing
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
| Original file line number | Diff line number | Diff line change |
|---|---|---|
|
|
@@ -163,6 +163,9 @@ def get_precision(input_number): | |
| :return: precision as int | ||
| """ | ||
| input_string = str(input_number) | ||
| if "e" in input_string.lower(): | ||
| mantissa, exponent = input_string.lower().split("e") | ||
| return max(0, get_precision(mantissa) - int(exponent)) | ||
| if "." in input_string: | ||
| splitted_input = input_string.split(".") | ||
| return len(splitted_input[1]) | ||
|
|
@@ -583,7 +586,7 @@ def filter_lambda(Input_Dict): | |
| print( | ||
| "[Warning] Opem Automatically Set Lambda To Maximum Value (23) ") | ||
| elif Input_Dict["lambda"] < 14: | ||
| Input_Dict["lambda"] = 23 | ||
| Input_Dict["lambda"] = 14 | ||
| print( | ||
| "[Warning] Opem Automatically Set Lambda To Minimum Value (14) ") | ||
| return Input_Dict | ||
|
|
@@ -739,6 +742,8 @@ def filter_range(IStart, IEnd, IStep): | |
| :type IStep: float | ||
| :return: filtered range as list | ||
| """ | ||
| if IStep == 0: | ||
|
Contributor
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Please remove this section |
||
| raise ValueError("[Error] Current step must not be zero") | ||
| temp = None | ||
| IStartO = IStart | ||
| IEndO = IEnd | ||
|
|
||
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
| Original file line number | Diff line number | Diff line change |
|---|---|---|
|
|
@@ -18,6 +18,12 @@ | |
| 0 | ||
| >>> get_precision(2.55) | ||
| 2 | ||
| >>> get_precision(1e-05) | ||
| 5 | ||
| >>> get_precision(1.5e-05) | ||
| 6 | ||
| >>> get_precision(1e+20) | ||
| 0 | ||
| >>> warning_check_1(-0.2, 10, 20, True) | ||
| [True, 10] | ||
| >>> warning_check_1(-0.2, 10, 20, False) | ||
|
|
@@ -42,7 +48,7 @@ | |
| {'alpha': 1} | ||
| >>> filter_lambda({"lambda":13}) | ||
| [Warning] Opem Automatically Set Lambda To Minimum Value (14) | ||
| {'lambda': 23} | ||
| {'lambda': 14} | ||
| >>> filter_alpha({"alpha":-0.1}) | ||
| [Warning] Opem Automatically Set Alpha To Maximum Value (0) | ||
| {'alpha': 0} | ||
|
|
@@ -52,6 +58,10 @@ | |
| [0, 500, 0.1] | ||
| >>> filter_range(500,0,-0.1) | ||
| [0, 500, 0.1] | ||
| >>> filter_range(0,100,0) | ||
|
Contributor
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Please remove this section |
||
| Traceback (most recent call last): | ||
| ... | ||
| ValueError: [Error] Current step must not be zero | ||
| >>> Input_dict=Get_Input({"T": "Cell Operation Temperature [K]", "PH2": "Partial Pressure [atm]", "PO2": "Partial Pressure [atm]"},input_item=input_test) | ||
| >>> Input_keys=list(Input_dict) | ||
| >>> Input_keys.sort() | ||
|
|
||
Oops, something went wrong.
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Move these lines under the
### Changedsection.