66 changes: 66 additions & 0 deletions agents/flow-cytometry-referee/README.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,66 @@
# Flow Cytometry Referee

Flow Cytometry Referee reviews standard FCS flow-cytometry files and supporting analysis material for technical
quality and reproducibility. It reports observed measurement and metadata evidence, missing controls, and gating
documentation gaps. It is designed for research QC and is not a clinical, diagnostic, regulatory, or assay-validation tool.

## Overview

Researchers often receive event files, a gating figure, and partial panel documentation from different systems. This
agent makes the technical review explicit: it inventories evidence, measures file-level QC facts, and identifies what
must be supplied before a gating workflow can be considered reproducible.

## Architecture

The prompt agent uses a parameterized Foundry chat model and the `flow-qc` Python environment. The environment reads
FCS events with `flowio`, calculates deterministic channel and acquisition summaries, validates the shape and channel
names of a stored spillover matrix when present, and can calculate an optional exploratory Isolation Forest outlier
fraction. The agent combines those results with supplied SOPs, gating plans, and control inventories. The outlier
score flags unusual measurement events only; it does not classify cells or samples or establish a QC threshold.

## Prerequisites

- An Azure subscription with Microsoft Discovery deployment permissions.
- An Azure AI Foundry project and a chat-model deployment for `{{CHAT-MODEL}}`.
- A container image built from `tools/flow-qc/Dockerfile` and published to the deployment ACR.
- Standard FCS files and, for a complete review, the acquisition template, panel specification, gating plan, and
single-stain, FMO, viability, and relevant biological controls.

## Configuration

| Parameter | Description | Example |
| --- | --- | --- |
| `{{CHAT-MODEL}}` | Foundry chat-model deployment | `gpt-4o-deployment` |
| `{{flowQcToolId}}` | Deployed Discovery tool ARM resource ID | `/subscriptions/.../tools/flow-qc` |

## Usage

1. Deploy the agent and the `flow-qc` tool through Discovery.
2. Supply one or more FCS files and the available supporting documents.
3. Ask for a technical review, for example: “Review this FCS file and gating plan for compensation evidence, control
coverage, acquisition integrity, and reproducibility gaps.”
4. Review PASS, WARN, NEEDS EVIDENCE, and FAIL findings with a qualified flow-cytometry scientist.

## Tools

`flow-qc` provides a Python code environment with `flowio`, NumPy, pandas, scikit-learn, and `flow_qc_utils`.
It can read standard FCS files, summarize event and channel values, inspect and validate stored compensation-related
metadata, evaluate acquisition-time continuity, calculate an exploratory event-outlier fraction, and create a
technical QC dashboard. A declared-range-limit fraction is a measurement-range check, not proof of detector
saturation. Derived reports belong in the configured output directory.

## Known Limitations

- It does not inspect microscopy images or imaging flow-cytometry imagery.
- It cannot prove compensation is correct from FCS metadata alone.
- It does not create, validate, or optimize gates without a documented gating plan and appropriate controls.
- It must not be used for diagnosis, treatment, patient triage, or regulatory release decisions.
- The unsupervised outlier metric is sensitive to panel design and batch effects and is not a trained classifier.

## Support

For issues or questions, open an issue at https://github.com/AzizMuminov/discovery/issues.

## Contributing

See [CONTRIBUTING.md](../../CONTRIBUTING.md) for the catalog contribution workflow.
70 changes: 70 additions & 0 deletions agents/flow-cytometry-referee/agent.yaml
Original file line number Diff line number Diff line change
@@ -0,0 +1,70 @@
kind: prompt
name: FlowCytometryReferee
displayName: Flow Cytometry Referee
description: >
An evidence-based technical reviewer for FCS quality, compensation, controls, and proposed gating plans.
model:
id: '{{CHAT-MODEL}}'
options:
temperature: 0
maxOutputTokens: 4096
instructions: |
You are the Flow Cytometry Referee, a technical quality-control agent for research flow-cytometry analysis.

Your job is to evaluate the reproducibility and technical adequacy of an FCS dataset and, when supplied, a
gating plan, panel description, control inventory, or laboratory SOP. You do not diagnose disease, classify
patients, recommend treatment, or claim that a dataset is biologically valid. Your findings concern only the
supplied data and documented analysis process.

## Operating rules
- Invoke only one tool at a time and wait for its result before the next tool call.
- For every FCS file, run the flow-qc Python environment before drawing conclusions about event count,
channels, compensation metadata, non-finite values, saturation, time ordering, or outlier score.
- Treat a missing document, control, or metadata field as missing evidence, never as proof of an error.
- Do not infer cell type, disease state, treatment effect, or sample identity from fluorescence values.
- Do not use the exploratory unsupervised outlier score as a classifier or a validated QC threshold. It identifies
unusual measurement events only.
- State panel- and instrument-specific assumptions explicitly. Ask for the acquisition template, gating plan,
and single-stain/FMO controls when their absence prevents a reliable review.

## Review sequence
1. Inventory the supplied FCS files and supporting material.
2. Run a QC script with flow_qc_utils.load_fcs and flow_qc_utils.build_qc_report.
3. Compare available evidence with this minimum technical checklist:
- event count and acquisition-time integrity;
- compensation or spillover metadata and single-stain controls;
- viability, singlet, debris, and relevant fluorescence-minus-one controls;
- documented gate order, parent populations, thresholds, and counts;
- transformations, exclusions, and batch/sample identifiers;
- reproducible output files and analysis software/version.
4. Return findings grouped as PASS, WARN, NEEDS EVIDENCE, or FAIL. Use FAIL only for a directly observed,
technically invalid condition such as an unreadable FCS file, no events, or non-finite event values that
make the requested analysis impossible.
5. Produce a concise remediation plan ordered by impact. Preserve the original data; write any derived JSON,
CSV, and figures to the output directory. When FCS event data is available, create a technical QC dashboard
with scatter, fluorescence-distribution, acquisition-time, and declared-range-limit panels through
`write_qc_artifacts`.

## Dashboard presentation
- Inspect the generated dashboard through the host's image viewer before finalizing the review.
- Treat dashboard, CSV, and JSON files as tool artifacts. Do not write Markdown image tags, `file:` URLs,
workspace-relative links, or guessed artifact paths: VS Code does not reliably resolve them in chat responses.
- If the host displays the dashboard as native image content, refer to that attached dashboard under a short
`## Dashboard` heading. Otherwise, report the artifact names without inventing a link.

## Required response format
- Scope and supplied evidence
- QC metrics observed from the FCS file
- Findings, each with severity, evidence, and remediation
- Missing evidence and the exact document or control needed
- Reproducibility checklist
- Limitations

Never present this report as clinical, regulatory, or diagnostic validation.
discoveryExtensions:
humanInTheLoop: Disabled
tools:
- toolId: '{{flowQcToolId}}'
confirmation: Disabled
disableDataHandlingTools: false
disableDiscoveryInjectedTools: false
19 changes: 19 additions & 0 deletions agents/flow-cytometry-referee/metadata.yaml
Original file line number Diff line number Diff line change
@@ -0,0 +1,19 @@
name: flow-cytometry-referee
type: agent
version: 1.0.0
associated_tools:
- agents/flow-cytometry-referee/tools/flow-qc
publisher:
name: Aziz Muminov
contact: azizbekmuminov52@gmail.com
support_url: https://github.com/AzizMuminov/discovery/issues
party: 3p
description: >
Reviews flow-cytometry FCS data and proposed gating plans for technical quality, compensation evidence,
control coverage, and reproducibility. Produces an evidence-backed QC report; it does not diagnose disease
or make clinical decisions.
tags:
- single-cell
- bioinformatics
- biomedical
- data-analysis
36 changes: 36 additions & 0 deletions agents/flow-cytometry-referee/tools/flow-qc/Dockerfile
Original file line number Diff line number Diff line change
@@ -0,0 +1,36 @@
FROM mcr.microsoft.com/azurelinux/base/python:3.12

ENV PYTHONUNBUFFERED=1
ENV PYTHONDONTWRITEBYTECODE=1
ENV MPLBACKEND=Agg
ENV MPLCONFIGDIR=/tmp/matplotlib
ENV OMP_NUM_THREADS=1
ENV MKL_NUM_THREADS=1
ENV OPENBLAS_NUM_THREADS=1

RUN tdnf -y update && \
tdnf -y install ca-certificates shadow-utils && \
update-ca-trust && \
tdnf clean all

RUN pip3 install --no-cache-dir \
flowio \
matplotlib \
numpy \
pandas \
scikit-learn \
scipy

RUN mkdir -p /app /workdir /input /output /tmp/matplotlib && \
chmod 755 /app /workdir /input /output

COPY flow_qc_utils.py /app/flow_qc_utils.py

RUN groupadd -r appuser && useradd -r -g appuser appuser && \
chown -R appuser:appuser /app /workdir /input /output /tmp/matplotlib

USER appuser
WORKDIR /workdir
ENV PYTHONPATH=/app

CMD ["/bin/bash"]
Loading